TY - CHAP U1 - Konferenzveröffentlichung A1 - Weidenmüller, Jens A1 - Himmel, Jörg A1 - Kanoun, Olfa A1 - Sehestedt, Christian T1 - Rod Shape Testing by High Frequency Eddy Current - Passive Impedance Measurement T2 - 6th International Multi-Conference on Systems, Signals and Devices N2 - For the rod shape measurement of hot rolled round steel bars (rods) the high frequency eddy current method is especially well suited as it requires no contact point and is not limited to below the Curie temperature. Defects of the rod's shape can be detected by measuring the impedance spectrum of the RLC-oscillator. In the first laboratory setup an Agilent impedance analyser was used for initial tests. Nevertheless, this setup cannot be applied in a steel plant due to the difficult environmental conditions. Hence, a vector network analyser for passive impedance measurement that is applicable in these surroundings was developed. Y1 - 2009 UR - https://ieeexplore.ieee.org/abstract/document/4956726 SN - 978-1-4244-4345-1 SB - 978-1-4244-4345-1 U6 - https://doi.org/10.1109/SSD.2009.4956726 DO - https://doi.org/10.1109/SSD.2009.4956726 SP - 5 S1 - 5 CY - Chemnitz ER -