Non-contacting Velocity Measurement of hot Rod and Wire using Eddy-current Sensors

  • Process diagnosis is an important method for improving product quality in rolling mills. In addition, the measurement of process variables such as roll gap, cross-sectional area, velocity, and volume flow of the material during production enables the implementation of model-based control concepts to improve product quality. The non-contact speed measurement of hot wire and bar is still a big challenge due to the rough environmental conditions and is solved mainly with optical measuring methods in production. The alternative measurement principle with eddy current sensors presented in this paper enables velocity measurement at locations in a rolling mill where optical measurement methods are not suitable.