For the rod shape measurement of hot rolled round steel bars (rods) the high frequency eddy current method is especially well suited as it requires no contact point and is not limited to below the Curie temperature. Defects of the rod's shape can be detected by measuring the impedance spectrum of the RLC-oscillator. In the first laboratory setup an Agilent impedance analyser was used for initial tests. Nevertheless, this setup cannot be applied in a steel plant due to the difficult environmental conditions. Hence, a vector network analyser for passive impedance measurement that is applicable in these surroundings was developed.
The transurethral resection (TUR) is a standard technique in urological treatment procedures. Both, monopolar and bipolar electrosurgical systems, are used for TUR. Whereas electrical and physical processes in surgery surroundings are well understood for monopolar systems, there is no sufficient data base for the assessment of the processes with the use of bipolar systems. In this context a multi-electrode measuring system was developed to visualize the spatial potential distribution around bipolar electrosurgical devices as a first step to risk analysis. To simulate the anatomic surroundings of a transurethral surgery a cylinder filled with isotonic saline solution was used as a complexity reduced experimental environment.
Die transurethrale Resektion der Prostata (TUR-P) ist der Gold Standard für die endoskopisch-chirurgische Behandlung der Benignen Prostatahyperplasie (BPH). Unbekannt ist jedoch, ob bei der bipolaren TUR-P die Möglichkeit von elektrothermischen Verletzung von benachbar-
tem nichtopertiertem Gewebe besteht. Grund hierfür könnten höhere Ausgangsleistungen der Chirurgie-Generatoren sein. Deshalb werden experimentell gemessene Werte der räumlichen Verlustleistungsdichte um ein bipolares Resektoskop als Quellterm für die Berechnung der Temperaturänderung im operationsnahen Gewebe verwendet. Die Temperaturberechnung basiert auf der numerischen Lösung der Wärmeleitungsgleichung nach Penne. Für die gewählten Randbedingungen und Eingabeparameter sind keine signifikanten Temperaturerhöhungen im Berechnungsgebiet am proximalen Ende des Resektoskop-Schaftes festzustellen. Um ein umfassendes Verständnis zu gewinnen sollen weiterführende Untersuchungen mit einer Variation der Randbedingungen und Eingabeparameter durchgeführt werden.
The transurethral resection (TUR) is a standard technique in urological treatment procedures. Both, monopolar and bipolar electrosurgical systems, are used for TUR. Whereas electrical and physical processes in surgery surroundings are well understood for monopolar systems, there is no sufficient data base for the assessment of the processes with the use of bipolar systems. In this context a multi-electrode measuring system was developed to visualize the spatial potential distribution around bipolar electrosurgical devices as a first step to risk analysis. To simulate the anatomic surroundings of a transurethral surgery a cylinder filled with isotonic saline solution is used as a complexity reduced experimental environment. Investigations about time stability and a qualitative assessment of the experimental set-up show deviations of measured values less than 5%. This is sufficient for further analysis of calculated power loss density distributions based on measured potential distributions. The spatial potential distribution around a bipolar devices is presented by horizontal and vertical sections through the experimental environment.
Die transurethrale Resektion der Prostata (TUR-P) ist der Gold Standard für die endoskopisch-chirurgische Behandlung der Benignen Prostatahyperplasie (BPH). Unbekannt ist jedoch, ob bei der bipolaren TUR-P die Möglichkeit von elektrothermischen Verletzung von benachbartem nichtopertiertem Gewebe besteht. Grund hierfür könnten höhere Ausgangsleistungen der Chirurgie-Generatoren sein. Deshalb werden experimentell gemessene Werte der räumlichen Verlustleistungsdichte um ein bipolares Resektoskop als Quellterm für die Berechnung der Temperaturänderung im operationsnahen Gewebe verwendet. Die Temperaturberechnung basiert auf der numerischen Lösung der Wärmeleitungsgleichung nach Penne. Für die gewählten Randbedingungen und Eingabeparameter sind keine signifikanten Temperaturerhöhungen im Berechnungsgebiet am proximalen Ende des Resektoskop-Schaftes festzustellen. Um ein umfassendes Verständnis zu gewinnen sollen weiterführende Untersuchungen mit einer Variation der Randbedingungen und Eingabeparameter durchgeführt werden
The bipolar transurethral resection is a further development of monopolar transurethral resection, being the gold standard in surgical treatment of prostate and bladder diseases. To create the metrological basis for understanding of electrical and physical processes during bipolar transurethral resection an experimental set-up to visualize spatial potential distribution around bipolar devices was developed. A hardware based signal conditioning and specific undersampling are presented as data acquisition methods for a sampling rate up to 1 MS/s. These methods are compared with the possibilities of a high speed data acquisition card. For more than four measuring channels and depending on the output bandwidth of the electrosurgical generator either hardware based signal conditioning or specific undersampling is suggested.