600 Technik
Refine
Year of publication
Document Type
- Conference Proceeding (15)
- Article (3)
- Book (1)
Language
- German (12)
- English (6)
- Multiple languages (1)
Has Fulltext
- no (19)
Is part of the Bibliography
- no (19)
Institute
Mobile Walzenmesstechnik
(2003)
In the field of magnetic inductance tomography,
signal processing is a real challenge. This is due to the divergent
nature of magnetic fields. The sensitivity, i.e. the change in the
receiving signal by means of an electrically conductive sample
in a measuring volume depends strongly on the positioning
of the sample. Objects that are located near the transmitting
or receiving coils are very well locatable, where objects in
larger distance are hard to detect. In this paper an approach
is presented that improves the topology of the magnetic fields
in the ”magnetic induction tomography” (MIT) by changing
geometric constructions and current patterns of coils so far,
as to allow a sharper localization of objects within the space.
The aim is to level the distribution of the sensitivity in the
measuring volume, so that electrically conductive objects with
a larger distance between transmitting and receiving unit can
be detected with almost the same signal intensity as objects
close to the transmitting and receiving unit. The simulation tool
Comsolic is used for the geometric modeling making a finite
element analysis (FEA). The subsequent signal processing and
analysis of the simulation results are implemented in Matlabic .
Within this FEA the coil geometries and current patterns are
changed numerically, so that the minimum object size, that is
still detectable, is, compared to the known MIT, reduced and the
sensitivity of the system is improved. To validate the simulation in
Comsolic , first simulation results are compared with analytical
models and analyses.
Methods of red-hot rod shape testing require a robust non-contact measurement principle as a touch point could lead to damages to the rod and the detection unit. Therefore a new basic approach based on high frequency eddy current (HFEC) has been investigated. Due to the robustness and the ability to determine the rod shape even above the Curie temperature this principle is especially well suited and can be implemented in the production process directly. The first automatic measurement setup was successfully developed with promising results. Hereby a defect of ovality was detected with a parallel RLC-oscillator. The capacity of this RLC-oscillator is constant whereas the inductance is the measurement part that varies due to eddy current interactions with the rod.
Fat content of liver is an essential parameter to decide whether a liver is suitable for transplantation or not. The determination of fat content is often challenging and usually there is not enough time to bring a specimen to a pathologic laboratory. That is why transplantation clinics need a technique to measure the fat content of a graft. In this paper the theoretical basics and an existing laboratory setup are presented.
The harmonic and interharmonic analysis recommendations are contained in the latest International Electrotechnical Commission (IEC) standards on power quality. Measurement and analysis experiences have shown that great difficulties arise in the interharmonics detection and measurement with acceptable levels of accuracy. In this paper, the spectral leakage problems of the discrete Fourier transform due to synchronization errors of interharmonics are analyzed. The time-domain averaging is investigated for the processing of harmonics in the framework of the IEC standards. A difference filter is proposed to detect interharmonics and can be compatible with the IEC standards. Simulations and the field results show the usefulness of the proposed methods.
The bipolar transurethral resection is a further development of monopolar transurethral resection, being the gold standard in surgical treatment of prostate and bladder diseases. To create the metrological basis for understanding of electrical and physical processes during bipolar transurethral resection an experimental set-up to visualize spatial potential distribution around bipolar devices was developed. A hardware based signal conditioning and specific undersampling are presented as data acquisition methods for a sampling rate up to 1 MS/s. These methods are compared with the possibilities of a high speed data acquisition card. For more than four measuring channels and depending on the output bandwidth of the electrosurgical generator either hardware based signal conditioning or specific undersampling is suggested.