With the introduction of Apple’s iPhone, gesture control became pop-
ular and was perceived as an intuitive means of interaction. Contact-
less gestures received broad attention with the X-Box Kinect.
Current technology is limited to a small number of uses, mainly
in entertainment systems. The target of this project is to increase the
range of possible applications, e.g. to the field of automotive,
industrial applications (manufacturing plants), assisted living in con-
texts ranging from private households to hospitals (interaction for
people with disabilities) and many more.
With a rapidly ageing population, it is increasingly important to de-
velop devices for elderly and disabled people that can support and aid
them in their daily lives, helping them to live at home as long as pos-
sible. The goal of this project is to implement a human-machine inter-
action and assistance system that can offer personalised health sup-
port for elderly people, or for those who have special needs in the
home environment.
To analyze the electric field around bipolar resectoscopes, used in urology, in terms of reasons for late complications after a surgical treatment a flexible multielectrode system was developed to measure the 3-D potential distribution. A high spatial resolution is achieved with the least possible individual measurements under the conditions of a quasi-static electric field. A flexible arrangement and positioning of the measuring points in the vertical direction of the experimental environment enable an adjustable spatial resolution and the selection of the region of interest. The existing influence of the multielectrode system on the measuring results is described and a correction method is presented to achieve significant results. Thus, the multielectrode system is usable for a comparative study of bipolar resectoscopes varying in the arrangement of resection and return electrode.
LEDs gelten als umweltfreundliche Beleuchtungstechnik. Für die Massenanwendung arbeiten die LED-Hersteller an einer Senkung der Kosten bzw. einer Erhöhung der Ausbeute, insbesondere bei der aufwendigen LED-Kristallbeschichtung auf den Wafern. Während der Beschichtung (MOCVD) werden optische In-situ-Messgeräte zur Überwachung des Prozesses genutzt. Die hier vorgestellte Untersuchung beschäftigt sich mit dem Einfluss von Super-Photolumineszenz-Effekten bei einer möglichen In-situ-Prozesskontrolle in der MOCVD.
Wirbelstromsensoren sind in der industriellen Messtechnik stark verbreitet. Insbesondere bei der Herstellung warmgewalzter Halbzeuge können sie durch ihre Robustheit gegenüber Wasserdampf und hohen Walzguttemperaturen überzeugen. Ein noch offenes Feld ist die In-Situ‐Detektion von Rissen im Draht während des Walzprozesses bei Walzgeschwindigkeiten bis zu 100 m/s und Materialtemperaturen bis zu 1200 ℃. Im Folgenden soll mittels der Finiten-Elemente-Analyse untersucht werden, wie sich Längsrisse im Draht auf Oberflächenströme und damit auf deren magnetische Flussdichte auswirken. Ziel ist es, Aussagen über den Einfluss verschiedener Rissbreiten und Risstiefen auf die magnetische Flussdichte zu machen und so einen möglichen Effekt auf einen Wirbelstromsensor untersuchen zu können.