To analyze the electric field around bipolar resectoscopes, used in urology, in terms of reasons for late complications after a surgical treatment a flexible multielectrode system was developed to measure the 3-D potential distribution. A high spatial resolution is achieved with the least possible individual measurements under the conditions of a quasi-static electric field. A flexible arrangement and positioning of the measuring points in the vertical direction of the experimental environment enable an adjustable spatial resolution and the selection of the region of interest. The existing influence of the multielectrode system on the measuring results is described and a correction method is presented to achieve significant results. Thus, the multielectrode system is usable for a comparative study of bipolar resectoscopes varying in the arrangement of resection and return electrode.
The bipolar transurethral resection is a further development of monopolar transurethral resection, being the gold standard in surgical treatment of prostate and bladder diseases. To create the metrological basis for understanding of electrical and physical processes during bipolar transurethral resection an experimental set-up to visualize spatial potential distribution around bipolar devices was developed. A hardware based signal conditioning and specific undersampling are presented as data acquisition methods for a sampling rate up to 1 MS/s. These methods are compared with the possibilities of a high speed data acquisition card. For more than four measuring channels and depending on the output bandwidth of the electrosurgical generator either hardware based signal conditioning or specific undersampling is suggested.
In the field of producing hot-rolled steel bars and wires, hot rolling mills are incomplete or barely equipped with measuring technology for recording relevant process parameters. Therefore, there is a big potential to increase product quality and to decrease costs and scrap by improving process control establishing new sensor systems. One of these crucial parameters is the roll gap,which is investigated as part of the research project PIREF. In this paper an experimental setup for examining the roll gap during a rolling process is presented and based on these results different sensor arrangements are discussed.
The transurethral resection (TUR) is a standard technique in urological treatment procedures. Both, monopolar and bipolar electrosurgical systems, are used for TUR. Whereas electrical and physical processes in surgery surroundings are well understood for monopolar systems, there is no sufficient data base for the assessment of the processes with the use of bipolar systems. In this context a multi-electrode measuring system was developed to visualize the spatial potential distribution around bipolar electrosurgical devices as a first step to risk analysis. To simulate the anatomic surroundings of a transurethral surgery a cylinder filled with isotonic saline solution was used as a complexity reduced experimental environment.
In the field of magnetic inductance tomography,
signal processing is a real challenge. This is due to the divergent
nature of magnetic fields. The sensitivity, i.e. the change in the
receiving signal by means of an electrically conductive sample
in a measuring volume depends strongly on the positioning
of the sample. Objects that are located near the transmitting
or receiving coils are very well locatable, where objects in
larger distance are hard to detect. In this paper an approach
is presented that improves the topology of the magnetic fields
in the ”magnetic induction tomography” (MIT) by changing
geometric constructions and current patterns of coils so far,
as to allow a sharper localization of objects within the space.
The aim is to level the distribution of the sensitivity in the
measuring volume, so that electrically conductive objects with
a larger distance between transmitting and receiving unit can
be detected with almost the same signal intensity as objects
close to the transmitting and receiving unit. The simulation tool
Comsolic is used for the geometric modeling making a finite
element analysis (FEA). The subsequent signal processing and
analysis of the simulation results are implemented in Matlabic .
Within this FEA the coil geometries and current patterns are
changed numerically, so that the minimum object size, that is
still detectable, is, compared to the known MIT, reduced and the
sensitivity of the system is improved. To validate the simulation in
Comsolic , first simulation results are compared with analytical
models and analyses.
The transurethral resection (TUR) is a standard technique in urological treatment procedures. Both, monopolar and bipolar electrosurgical systems, are used for TUR. Whereas electrical and physical processes in surgery surroundings are well understood for monopolar systems, there is no sufficient data base for the assessment of the processes with the use of bipolar systems. In this context a multi-electrode measuring system was developed to visualize the spatial potential distribution around bipolar electrosurgical devices as a first step to risk analysis. To simulate the anatomic surroundings of a transurethral surgery a cylinder filled with isotonic saline solution is used as a complexity reduced experimental environment. Investigations about time stability and a qualitative assessment of the experimental set-up show deviations of measured values less than 5%. This is sufficient for further analysis of calculated power loss density distributions based on measured potential distributions. The spatial potential distribution around a bipolar devices is presented by horizontal and vertical sections through the experimental environment.
The harmonic and interharmonic analysis recommendations are contained in the latest International Electrotechnical Commission (IEC) standards on power quality. Measurement and analysis experiences have shown that great difficulties arise in the interharmonics detection and measurement with acceptable levels of accuracy. In this paper, the spectral leakage problems of the discrete Fourier transform due to synchronization errors of interharmonics are analyzed. The time-domain averaging is investigated for the processing of harmonics in the framework of the IEC standards. A difference filter is proposed to detect interharmonics and can be compatible with the IEC standards. Simulations and the field results show the usefulness of the proposed methods.
Fat content of liver is an essential parameter to decide whether a liver is suitable for transplantation or not. The determination of fat content is often challenging and usually there is not enough time to bring a specimen to a pathologic laboratory. That is why transplantation clinics need a technique to measure the fat content of a graft. In this paper the theoretical basics and an existing laboratory setup are presented.