Refine
Document Type
- Article (6)
- Bachelor Thesis (2)
- Book (2)
- Conference Proceeding (1)
Language
- English (11) (remove)
Has Fulltext
- yes (11) (remove)
Is part of the Bibliography
- no (11)
Institute
- Fachbereich 4 - Institut Mess- und Senstortechnik (11) (remove)
In this scientific research, an innovative sensor system is developed to prevent child heatstrokes in vehicles. The system incorporates a 24 GHz Continuous-Wave (CW) radar system, which identifies vital signs of an infant through a 4-by-1 patch antenna array embedded in a specifically designed circuit board. Intelligent signal processing algorithms analyze data generated by the radar chip and execute processing tasks on a robust microcontroller. The child’s respiration
rate can be extracted qualitatively from the data in nearly real-time, enabling the system to differentiate between a child and a mere shopping bag on the seat. In the event of identifying a critical condition, the system transmits this information via a data bus to a central ECU within the vehicle. This ECU is integrated with GSM and GPS connections, allowing communication with the driver or emergency services. The development of the sensor system adheres to existing
automotive industry standards, featuring a cost-effective design intended as a prototype for large-scale production. Through rigorous evaluation across various scenarios, including realworld
situations with children, the sensor system is refined. The continuously reliable function of the developed radar-based sensor system holds the potential to save children’s lives, making
a major contribution to automotive safety.
The highly successful lecture series on the topic of measurement and sensor technologies as part of the IEEE Workshop at the University of Applied Sciences Ruhr West (HRW) is being continued in collaboration with the University of Siegen, the TU Chemnitz and the ITMO National Research University of Information Technologies, Mechanics and Optics in St. Petersburg. This time the event is featuring an even more international orientation by linking it with the Russian SENSORICA. The topics cover industrial and medical measurement technology as well as sensor technology in vehicles. Our event offers a platform for knowledge transfer between industry and public and commercial research institutions in the area of measurement technology.
This Abstract Book offers the opportunity of contacting speakers even after the event.
In addition we are very pleased to have selected contributions published in a special edition of the journal „tm Technisches Messen“ (De Gruyter Oldenbourg Verlag) again this year.
Detection of air trapping in chronic obstructive pulmonary disease by low frequency ultrasound
(2012)
Background: Spirometry is regarded as the gold standard for the diagnosis of COPD, yet the condition is widely underdiagnosed. Therefore, additional screening methods that are easy to perform and to interpret are needed. Recently, we demonstrated that low frequency ultrasound (LFU) may be helpful for monitoring lung diseases. The objective of this study was to evaluate whether LFU can be used to detect air trapping in COPD. In addition, we evaluated the ability of LFU to detect the effects of short-acting bronchodilator medication.Methods: Seventeen patients with COPD and 9 healthy subjects were examined by body plethysmography and LFU. Ultrasound frequencies ranging from 1 to 40 kHz were transmitted to the sternum and received at the back during inspiration and expiration. The high pass frequency was determined from the inspiratory and the expiratory signals and their difference termed F. Measurements were repeated after inhalation of salbutamol.Results: We found signi ficant differences in F between COPD subjects and healthy subjects. These differences were already significant at GOLD stage 1 and increased with the severity of COPD. Sensitivity for detection of GOLD stage 1 was 83% and for GOLD stages worse than 1 it was 91%. Bronchodilator effects could not be detected reliably.Conclusions: We conclude that low frequency ultrasound is cost-effective, easy to perform and suitable for detecting air trapping. It might be useful in screening for COPD
Photoluminescence (PL) in GaN or InGaN layers monitored during epitaxial growth at high temperatures permits a quasi-continuous in situ characterization of opto-electronic properties. Therefore, epitaxial parameters can now be optimized at the earliest possible stage. A pulsed and high-power UV laser was required for PL excitation at high temperatures. Herein, the underlying nonlinear mechanism was studied via time-resolved PL experiments and rate equation-based modeling. A temperature-activated and saturable path for quenching over defects was identified. Beyond the saturation threshold, reasonably-intensive PL sets in. At high temperatures not only is the near band gap-PL present, but also—as a new observation—a defect-assisted PL emerges. Apart from these specific electronic transitions in high-temperature PL of GaN, a simple, but reasonably predictive model of the luminescent thin film has been set up to track down interference fringes in the PL spectra. It is worth mentioning that the spectral PL modulation (aiming at the Purcell effect) is often mixed up with ordinary Fabry–Pérot interference. A distinction has become key to properly analyze the spectral signatures of high-temperature PL in order to provide a reliable in situ characterization of GaN layers during epitaxial growth
This experimental study demonstrates for the first time a solid-state circuitry and design for a simple compact copper coil (without an additional bulky permanent magnet or bulky electromagnet) as a contactless electromagnetic acoustic transducer (EMAT) for pulse echo operation at MHz frequencies. A pulsed ultrasound emission into a metallic test object is electromagnetically excited by
an intense MHz burst at up to 500 A through the 0.15 mm filaments of the transducer. Immediately thereafter, a smoother and quasi “DC-like” current of 100 A is applied for about 1 ms and allows an
echo detection. The ultrasonic pulse echo operation for a simple, compact, non-contacting copper coil is new. Application scenarios for compact transducer techniques include very narrow and
hostile environments, in which, e.g., quickly moving metal parts must be tested with only one, non-contacting ultrasound shot. The small transducer coil can be operated remotely with a cable
connection, separate from the much bulkier supply circuitry. Several options for more technical and fundamental progress are discussed.
A Large and Quick Induction Field Scanner for Examining the Interior of Extended Objects or Humans
(2017)
This study describes the techniques and signal properties of a large, powerful, and linear-scanning 1.5 MHz induction field scanner. The mechanical system is capable of quickly reading the volume of relative large objects, e.g., a test person. The general approach mirrors Magnetic Induction Tomography (MIT), but the details differ considerably from currently-described MIT systems: the setup is asymmetrical, and it operates in gradiometric modalities, either with coaxial excitation with destructive interference or with a single excitation loop and tilted receivers. Following this approach, the primary signals were almost completely nulled, and test objects' real or imaginary imprint was obtained directly. The coaxial gradiometer appeared advantageous: exposure to strong fields was reduced due to destructive interference. Meanwhile, the signals included enhanced components at higher spatial frequencies, thereby obtaining a gradually improved capability for localization. For robust signals, the excitation field can be powered towards the rated limits of human exposure to time-varying magnetic fields. Repeated measurements assessed the important signal integrity, which is affected by the scanner´s imperfections, particularly any motions or respiratory changes in living beings during or between repeated scans. The currently achieved and overall figure of merit for artifacts was 58 dB for inanimate test objects and 44 dB for a test person. Both numbers should be understood as worst case levels: a repeated scan with intermediate breathing and drift/dislocations requires 50 seconds, whereas a single measurement (with respiratory arrest) takes only about 5 seconds.
In this work we report the first quasi-continuous in-situ photoluminescence study of growing InGaN LED structures inside an industrial-grade metal-organic vapor phase epitaxy (MOVPE) reactor at growth temperature. The photoluminescence spectra contain information about temperature, thickness and composition of the epitaxial layers. Furthermore, the in-situ spectra – even at an early stage of the growth of the active region – can be used to predict the photoluminescence emission wavelength of the structure at room temperature. In this study an accuracy of this predicted wavelength in the range of ± 1.3 nm (2σ) is demonstrated. This technique thus appears suitable for closed-loop control of the emission wavelength of InGaN LEDs already during growth.
A simple copper coil without a voluminous stationary magnet can be utilized as a non-contacting transmitter and as a detector for ultrasonic vibrations in metals. Advantages of such compact EMATs without (electro-)magnet might be: applications in critical environments (hot, narrow, presence of iron filings…), potentially superior fields (then improved ultrasound transmission and more sensitive ultrasound detection).
The induction field of an EMAT strongly influences ultrasound transduction in the nearby metal. Herein, a simplified analytical method for field description at high liftoff is presented. Within certain limitations this method reasonably describes magnetic fields (and resulting eddy currents, inductances, Lorentz forces, acoustic pressures) of even complex coil arrangements. The methods can be adapted to conventional EMATS with a separate stationary magnet.
Increased distances (liftoff) are challenging and technically relevant, and this practical question is addressed: with limited electrical power and given free space between transducer and target metal, what would be the most efficient geometry of a circular coil? Furthermore, more complex coil geometries (“butterfly coil”) with a concentrated field and relatively higher reach are briefly investigated.