Stationäre Rohrströmungen
(2024)
Im Rahmen der vorliegenden Bachelorarbeit in Kooperation mit der Hospitaltechnik Planungsgesellschaft mbH wurden die möglichen Effekte eines verteilten Alarmsystems von Dräger und tetronik auf die Arbeitsqualität der Pflegekräfte auf Intensivstationen untersucht.
Dazu wurde eine Online-Befragung via Microsoft Forms mit den Intensivpflegekräften der Karl-Hansen-Klinik in Bad Lippspringe und der Spezialklinik Jugenheim in Jugenheim durchgeführt. Hierbei besitzt die Intensivstation Bad Lippspringe das verteilte Alarmsystem der
Unternehmen Dräger und tetronik, wohingegen die Intensivstation Jugenheim keins besitzt. Mit Hilfe selbstständig durchgeführter Interviews wurden sowohl die befragten Intensivstationen in
ihrem Aufbau dargestellt als auch das verteilte Alarmsystem in seiner Beschaffenheit und Funktion vollständig erläutert. Die Daten aus der Online-Befragung wurden mit Hilfe eines einseitigen Zweistichproben t-Tests ungleicher Varianzen ausgewertet.
Die Auswertung der Online-Befragung ergab acht signifikante Ergebnisse, die auf eine bessere Arbeitsqualität in der Intensivstation mit dem verteilten Alarmsystems von Dräger und tetronik hinweisen. Jedoch fiel die Mehrheit der 25 Mittelwertsunterschiede nicht signifikant aus.
Schlussfolgernd ist davon auszugehen, dass der positive Effekt eines verteilten Alarmsystems auf Intensivstationen noch nicht zu genüge erreicht ist. Es ist daher anzustreben, dass das verteilte Alarmsystem weiterhin verbessert wird, sodass auch die restlichen untersuchten
Effekte signifikant werden.
In dieser Arbeit wird das Problem der "Kontrolle mehrerer Quadrokopter zur Durchführung einer kooperativen Aktion"diskutiert. Das Hauptproblem dieses Themas ergibt sich aus der Komplexität der Positionsbestimmung und Identifizierung von Quadrokopter, insbesondere in komplexen Umgebungen bei der Durchführung kooperativer Aktionen.
Ziel ist durch Python die Entwicklung eines Verfolgungs- und Steuerungssystems, bei dem einer der Haupt-Quadrokopter (grüne Farbe) von einer Handy-App gesteuert wird und jede beliebige Position anfliegen kann, während die anderen Quadrokopter (rot markiert) ihm automatisch folgen und eine bestimmte Formation einhalten, so
dass eine Zusammenarbeit möglich ist. Diese automatische Verfolgung basiert auf der Positionserfassung des Quadrokopters durch zwei feste Kameras im Raum und der Ausführung der zugehörigen Algorithmen.
Die in diesem Beitrag vorgeschlagene Methode basiert auf der Farbsegmentierung zur Erkennung von Quadrokoptern und zur Bestimmung ihrer Weltkoordinaten mit Hilfe eines konvergenten binokularen Kamerasystems. Durch Anwendung der Stereo-Vision- Matching-Methode, die auf dem Global-Optimum-Algorithmus basiert, wird der Abgleich
der Bilder abgeschlossen und die Weltkoordinaten aller Quadrokoptern werden bestimmt. Schließlich folgt der rote Quadrokopter der Bewegung des Hauptquadrokoptern und arbeitet mit ihm zusammen, um die vorgegebene Aufgabe zu erfüllen. Am Ende dieses Artikels wird deutlich, wie das System entworfen, entwickelt und getestet wurde.
Im Rahmen dieser Arbeit wird zunächst ein Überblick über die Grundlagen des maschinellen Lernens und über verschiedene Methoden der digitalen Bildqualitätsbewertung gegeben.
Eine dieser Methoden wird näher betrachtet und es werden mögliche Probleme für das Training von neuronalen Netzwerken, insbesondere von Netzwerken zur Bildqualitätsbewertung herausgearbeitet.
Dieses Problem wird quantifiziert und es werden zwei grundlegende Verfahren zur Lösung entworfen. Dabei wird jeweils ein separates Konzept entwickelt und ausgewertet.
Die beiden Ansätze werden in einem direkten Vergleich unter verschiedenen Gesichtspunkten gegenübergestellt und es wird der vielversprechendere davon ausgewählt.
Der ausgewählte Lösungsansatz wird implementiert und in ein bereits existierendes Netzwerk zur Bildqualitätsbewertung integriert. Die Leistung des modifizierten Netzwerkes wird mit dem Original verglichen.
Sensor-/Aktorsystem zur Überwachung und Unterstützung der Thermoregulation von Intensivpatienten
(2023)
Diese Bachelorarbeit ist dem Thema Sensor-/Aktorsystem zur Überwachung und Unterstützung von Intensivpatienten gewidmet, einem Bereich, der durch schnelle Fortschritte in der Technologie und der Biomedizin beeinflusst wird. Hier bildet die Körperkerntemperatur einen entscheidenden Bestandteil und einen bedeutenden physiologischen Parameter, der nicht nur für die Funktion des menschlichen Körpers wesentlich ist, sondern auch wertvolle Informationen über den Gesundheitszustand eines Patienten liefert. Im Rahmen dieser Arbeit werden sowohl die physiologische Bedeutung als auch die technologischen Methoden zur Messung der Körperkerntemperatur behandelt. Das Ziel ist, ein Verständnis für die Notwendigkeit einer präzisen Überwachung dieser Parameter bei Intensivpatienten zu entwickeln, indem die Grundlagen der Körperkerntemperatur und ihre Bedeutung für den Organismus im Fokus stehen. Die Einbeziehung von Sensor- und Aktorsystemen in die Intensivmedizin verspricht eine bessere Pflege und klinische Entscheidungsfindung, was zu optimierten Behandlungsergebnissen führen kann. Das Thema der vorliegenden Arbeit hat eine Relevanz für die moderne Gesundheitsversorgung und intendiert wird, Einblicke in innovative Ansätze zur Verbesserung der Pflege von Intensivpatienten zu bieten. Zudem soll die Gesundheitsversorgung der allgemeinen Gesellschaft weiter vorangebracht werden.
In this scientific research, an innovative sensor system is developed to prevent child heatstrokes in vehicles. The system incorporates a 24 GHz Continuous-Wave (CW) radar system, which identifies vital signs of an infant through a 4-by-1 patch antenna array embedded in a specifically designed circuit board. Intelligent signal processing algorithms analyze data generated by the radar chip and execute processing tasks on a robust microcontroller. The child’s respiration
rate can be extracted qualitatively from the data in nearly real-time, enabling the system to differentiate between a child and a mere shopping bag on the seat. In the event of identifying a critical condition, the system transmits this information via a data bus to a central ECU within the vehicle. This ECU is integrated with GSM and GPS connections, allowing communication with the driver or emergency services. The development of the sensor system adheres to existing
automotive industry standards, featuring a cost-effective design intended as a prototype for large-scale production. Through rigorous evaluation across various scenarios, including realworld
situations with children, the sensor system is refined. The continuously reliable function of the developed radar-based sensor system holds the potential to save children’s lives, making
a major contribution to automotive safety.
Entwicklung einer Simulationsumgebung zur Ermittlung der Verluste Moderner Leistungstransistoren
(2023)
In dieser Bachelorarbeit liegt der Fokus auf der Simulation von Leistungselektronikkomponenten, wobei insbesondere MOSFETs und IGBTs im Mittelpunkt stehen. Der Verwendung von modernen Leistungshalbleiterbauteilen in elektrischen Schaltungen kommt eine immer größere Bedeutung zu, da sie die Effizienz und Leistungsfähigkeit von Energiewandlern und Invertern maßgeblich beeinflussen. Um ihre Funktionalität und Leistung unter verschiedenen Bedingungen zu verstehen und optimieren zu können, ist die Simulation ein unverzichtbares Werkzeug.
Ein wesentlicher Schwerpunkt liegt auf dem Vergleich zwischen Silizium (SI) und Siliziumkarbid (SiC) MOSFETs in einem Halbbrücken-Inverter. Hierbei werden Simulationen unter verschiedenen Temperaturen durchgeführt, um die Auswirkungen von Temperaturschwankungen auf das Verhalten dieser Transistoren zu untersuchen. Die Ergebnisse ermöglichen Einblicke in die Leistungsfähigkeit und Vor- und Nachteile der beiden Materialien in unterschiedlichen Anwendungen.
Des Weiteren wird die Simulation eines IGBTs (Insulated Gate Bipolar Transistor) eingehend untersucht. Dies umfasst die Analyse seiner elektrischen Eigenschaften sowie die Simulation und Darstellung der Einschaltverluste (EON) und Ausschaltverluste (EOFF). Die Simulationen werden mithilfe von LTspice durchgeführt, und die Verluste werden numerisch in MATLAB integriert. Diese Untersuchungen tragen dazu bei, das Verhalten von IGBTs in Schaltungen besser zu verstehen und tragen zur Optimierung von Leistungselektroniksystemen bei.
Die vorliegende Arbeit bietet somit einen umfassenden Einblick in die Simulation und Analyse von Leistungselektronikkomponenten unter verschiedenen Bedingungen und trägt zur Entwicklung effizienterer und zuverlässigerer elektrischer Schaltungen bei.
Diese Arbeit konzentriert sich auf die Erstellung einer umfassenden technischen Dokumentation für ein Medizinprodukt der Klasse IIa gemäß den Anforderungen der Medical Device Regulation (MDR) 2017/745. Das Hauptziel besteht darin, eine konforme Dokumentation zu entwickeln, die alle wesentlichen Aspekte der Produktentwicklung, Herstellung und Verwendung abdeckt. Besonderes Augenmerk wird darauf gelegt, die regulatorischen Anforderungen der MDR zu erfüllen, um die Sicherheit und Wirksamkeit des Produkts zu gewährleisten und eine Zulassung für den europäischen Markt zu ermöglichen. Die verschiedenen Bestandteile der technischen Dokumentation, einschließlich klinischer Bewertungen, Risikomanagement, Validierungstests, Konformitätsbewertungen und Kennzeichnung, werden gründlich untersucht. Es wird eine systematische und strukturierte Herangehensweise präsentiert, um eine erfolgreiche Konformitätsbewertung für das hier beschriebene Medizinprodukt der Klasse IIa zu erreichen. Die Ergebnisse dieser Arbeit tragen dazu bei, die Qualität und Sicherheit des hier bearbeiteten Medizinproduktes der Klasse IIa zu verbessern und somit die Patientensicherheit zu gewährleisten.
In der modernen Medizintechnik ist die zuverlässige Funktionsweise von Geräten von entscheidender Bedeutung. Diese Bachelorarbeit befasst sich mit dem Zustandsmonitoring von medizinischen Geräten, um die verschiedenen Zustände von medizinischen Geräte zu erfassen.
Das Monitoring hilft dabei, die tatsächliche Nutzungsfrequenz der Geräte zu ermitteln. Ein verbessertes Verständnis der Gerätenutzung kann dazu beitragen, Kosten zu senken und das Gerätemanagement in Krankenhäusern zu optimieren.
Das primäre Ziel dieser Arbeit war die Entwicklung einer Datenverarbeitungsmethode für das Zustandsmonitoring von Medizingeräten mittels energiesparender Funk-Sensoren. Oftmals werden in Krankenhäusern mehr Geräte angeschafft als benötigt, und dennoch müssen alle Geräte gewartet werden, selbst wenn einige selten in Betrieb sind. Dies resultiert in unnötigen Kosten und Ausfallzeiten.
Für die Untersuchung wurde ein energiesparender Funksensor eingesetzt, der mit einem Stromsensor ausgestattet ist. Dieser erfasst den Stromfluss der angeschlossenen Geräte und kommuniziert online über das IoT. Die erfassten Daten wurden komprimiert und an das TTN (The Things Network) übertragen. Ein KI-Modell wurde mit den gesammelten Daten trainiert, um die verschiedenen Zustände der Geräte zu erkennen.
Die wichtigsten Ergebnisse zeigen, dass die Zustände der Geräte variieren und typischerweise in "AN", "AUS", "Idle-Modus" und "Im Betrieb" kategorisiert werden können. Sobald der Stromfluss einen bestimmten Wert erreicht, kann die KI bestimmen, in welchem Zustand sich das Gerät befindet. Dies bietet eine wertvolle Grundlage für ein verbessertes Management und Wartungssystem in Krankenhäusern.
Um die Ziele der Bachelorarbeit schrittweise zu erreichen, wird im Folgenden eine Einführung in die DIN EN 80001-1 gegeben. Danach wird die Methode zur Einführung der Norm im AGAPLESION DIAKONIEKLINIKUM ROTENBURG präsentiert, wobei auf die Struktur der Dokumentation und die Einführung der Prozesse eingegangen wird. Im letzten Schritt wird die Implementierung anhand eines Beispiels durchgeführt. Hierbei wird geprüft, wie gut die Norm umsetzbar ist und welche Probleme dabei auftreten. In der Zusammenfassung werden alle Informationen verknüpft und die daraus resultierenden Probleme vorgestellt und anschließend diskutiert.
Inverter auf Basis der Pulsweitenmodulation dominieren in dem heutigen Stand der Technik. Wie bei den meisten elektronischen Einrichtungen entstehen während ihres Betriebs mehr oder weniger ungewollte Störungen, welche zur Beeinträchtigung der Funktion von anderen Geräten oder elektronischen Schaltungen führen. Die dafür angewandten technischen Gegenmaßnahmen scheinen meist aufwandmäßig hoch zu sein insbesondere bei kritischen elektrischen Einrichtungen. Dank der Resonanzinvertertopologie wird dieser Aufwand zum größten Teil erspart. Der Aufbau und die Funktionsweise der beiden Invertertopologien werden einzeln erläutert. Nach einigen Simulationsdurchführungen, welche unter verschiedenen Betriebsfrequenzen nacheinander erfolgen, werden die beiden Inverter gegenübergestellt und Mithilfe der Simulationsergebnisse verglichen. Aus den allgemeinen Vergleichen stellt sich heraus, dass die Resonanzinvertertopologie insbesondere bei niedrigen Frequenzen im EMV-Aspekt sowie unter Betrachtung der Leistungsfähigkeit den SVPWM-Inverter gewinnt. Während der Resonanzinverter in den niedrigen Frequenzen mehr Störaussendungen als der SVPWM-Inverter produziert, ist das Phänomen bei höheren Frequenzen eher invers.
Für eine Automatisierung des Walzvorgangs von rundem Walzgut muss die Geschwindigkeit bekannt sein. Wegen der gekrümmten Oberfläche von rundem Walzgut können nicht die gleichen Verfahren wie bei flachem Walzgut verwendet werden, ohne negativen Einfluss auf die Toleranz und Sicherheit zu nehmen. Unter Berücksichtigung der Umgebung des Walzwerks wurden zwei Kantendetektoren entwickelt, die einen Puls erzeugen, dessen Dauer der Zeit entspricht, die der Anfang oder das Ende des Walzguts vom ersten bis zum zweiten Kantendetektor benötigt. Durch den bekannten Abstand zwischen der Sensoren kann auf diese Weise über die Zeit die Geschwindigkeit berechnet werden. In dieser Arbeit wurde eine Auswerteelektronik entwickelt, die diese Zeit Intervalle mit einer Auflösung von 5 ns und einer maximalen Abweichung unter 0,002 % messen kann. Sie verwendet einen Synchrongleichrichter, wodurch verrauschte Signale gemessen werden können und einen 32-Bit Timer, der mit einer 200 MHz Taktquelle betrieben wird. Um die Kantendetektoren anzuregen wurde ein DDS implementiert, der 10V Sinussignale bis zu 20 MHz generieren kann. Alle digitalen Schaltungen wurden in einem FPGA implementiert.
Im Rahmen dieser Bachelorarbeit werden Dehnungsmessstreifen (DMS)
mittels Faktor kalibriert, da die DMS unterschiedlich positioniert sind. Auf
Grund der manuellen Applikation stellen die DMS unterschiedliche Dehnungen
dar, dies soll mit Hilfe einer Kalibrierung der DMS verhindert werden. Damit
die DMS kalibriert werden können, werden die DMS in einer Viertelbrücke
gemessen und anschließend mit Hilfe einer Messkarte in Matlab eingelesen.
Im Matlab werden die Daten anschließend weiterverarbeitet, so dass jeder
DMS seinen eigenen Faktor bekommt. Anschließend werden die DMS in eine
Vollbrücke und Zweiviertelbrücke verrechnet, damit die reine Biegedehnung
sowie reine Zugdehnung berechnet werden kann.
In dieser Arbeit wird die Thematik Datenvisualisierung von Wissensgraphen behandelt. Durch den massiven Datenbestand in der heutigen Zeit und der immer stärker werdenden Digitalisierung ist die Notwendigkeit gestiegen, aus Daten effizient Wissen generieren zu können. Folglich wurde repräsentativ eine Graphbibliothek ausgewählt, um die Daten zu visualisieren. Umgesetzt wurde die Programmierung durch ein JavaScript Framework. Die Daten einer Wissensdatenbank wurden vom Betreuer bereitgestellt. Das übergeordnete Ziel der Arbeit ist eine verbesserte Darstellung von Wissensdaten in Form eines Wissensgraphen. Sinn und Zweck dahinter ist es, Beziehungen zwischen Daten verbessert erkennen zu können und gleichzeitig Informationen zu gewinnen, die auf den ersten Blick nicht sofort erkennbar sind.
Ziel dieser Arbeit ist es, ein grundlegendes Verständnis eines elektrisch betriebenen Lenksystems zu schaffen und dessen zugehörige Anforderungen und Analysen seitens der funktionalen Sicherheit darzustellen. Beginnend mit der theoretischen Darstellung des Lenksystems und den Normen wird im praktischen Teil der Arbeit diese Theorie angewandt. Zudem werden Autonomiestufen und deren rechtliche Grundlage in Deutschland aufgeführt und diskutiert.
Hierbei wird auf die Norm für die funktionale Sicherheit, die ISO 26262 und auf die Norm für die Sicherheit der Funktion, die ISO 21448 eingegangen. Es wird erläutert, welchen Zweck die Anwendung der ISO 26262 hat und wie sie aufgrund der zunehmenden Komplexität in der Automobilbranche durch die ISO 21448 (SOTIF) ergänzt wird. Dazu wird herausgearbeitet, wann die ISO 26262 an ihre Grenzen stößt und wie unabdingbar die Anwendung von SOTIF wird.
Einhergehend mit der technologischen Entwicklung und der zunehmenden Komplexität treten nämlich vermehrt Aspekte auf, die mit der ISO 26262 allein nicht abgedeckt werden können. Sicherheitsaspekte nehmen zu und verändern sich mit neuen Komfort- und Assistenzsystemen kontinuierlich. Daher ist es auf-grund der sich ändernden Technologien und derer Komplexität unabdingbar, bestehende Ansätze zu verbessern und zusätzliche neue Methoden für die Sicherheit des Endproduktes zu entwickeln und neben den etablierten Methoden anzuwenden.
Welchen Einfluss dies auf ein modernes Lenksystem hat und wie in diesem Zusammenhang das Zusammenspiel der ISO 26262 und ISO 21448 mit klassischen Methoden wie der Fehlermöglichkeits- und Einflussanalyse (FMEA) betrachtet werden muss, wird in dieser Arbeit dargestellt. Automobilhersteller sind heute bereits in der Lage Fahrzeuge automatisiert in bestimmten Betriebsgrenzen und Bereichen fahren zu lassen. Doch was muss getan werden, um sämtliche Betriebsgrenzen aufzuheben und ein Fahrzeug „autonom“ zu gestalten? Regulatorien, Standards und Richtlinien sind bereits heute auf dem besten Weg dorthin, doch ist es in der Praxis tatsächlich realisierbar?
Mit dieser Arbeit sollen unterschiedliche Einflussfaktoren und deren Auswirkung auf die Zuverlassigkeit
der mechanischen und elektrischen Bauteile eines Bohrmoduls aufgezeigt und miteinander verglichen werden.
Dazu werden zwei Zuverlassigkeitsanalysen mit je zwei verschiedenen Szenarien durchgeführt und
ausgewertet.
Das Szenario basiert auf der von der National Aeronautics and Space Administration (NASA) geplanten
Mission die Mondoberfläche und ihre oberen Gesteinsschichten zu analysieren. Zur Bewältigung dieser
Aufgabe soll ein mobiler Roboter mit einem Bohrmodul ausgestattet werden, um an unterschiedlichen Orten
auf der Mondoberfläche Bodenproben zu analysieren. Es sollen die Bohrungen bis zu einem Meter Tiefe durchgeführt werden. Ziel der Mission soll sein, die Geologie des Mondes zu erforschen [1].
Dieses Szenario dient als Grundlage die Zuverlässigkeit des Bohrmoduls unter extremen Bedingungen
zu ermitteln. Dabei stellt sich die Frage danach, welchen Einfluss verschiedene Temperaturen und
weitere Faktoren auf die Zuverlässigkeit des Bohrmoduls haben.
Das Ziel dieser Arbeit ist die Durchfuhrung einer Zuverlässigkeitsanalyse eines Bohrmoduls unter Hinzunahme
zwei verschiedener Standards unterschiedlicher Herangehensweisen. Dabei gibt jeder Standard eine
andere Art der Durchführung vor. Dabei ist das NSWC-10 stark abhängig von den konstruktiven Eigenschaften,
der FIDES von den vorherrschenden Umweltgegebenheiten. Die Analysen der Zuverlässigkeit
des Bohrmoduls werden sowohl für ein Erdszenario als auch für ein Mondszenario mit ihren jeweiligen
unterschiedlichen Gegebenheiten durchgeführt. Während der Analysen werden weitere Einflussfaktoren in
den Berechnungen berücksichtigt, die in den Standards als solche nicht aufgeführt werden. Zu diesen zählen
unter anderen die Temperaturschwankung auf dem Mond und das dort vorherrschende Vakuum. Diese
finden Berücksichtigung, um die extremen Bedingungen des Mondszenarios besser repräsentieren zu können.
Letztlich werden die beiden Standards hinsichtlich ihrer Anwendbarkeit auf jene Szenarien bewertet,
die ermittelten Ausfallraten erläutert und die Einflussfaktoren miteinander verglichen.
Zur Ermittlung der Zuverlässigkeit des Moduls werden vorab die Szenarien definiert und die konstruktiven
Eigenschaften der Bauteile ermittelt. Anschliesend wird die erste Zuverlässigkeitsanalyse mit
Hilfe des NSWC-10 durchgeführt. Dazu werden die einzelnen Ausfallraten der Bauteile bestimmt und verglichen.
Neben den vorgegeben Einflussfaktoren werden, falls möglich, spezifische Gegebenheiten des
Szenarios auf dem Mond einbezogen und diskutiert. Die zweite Zuverlässigkeitsanalyse erfolgt auf der
Grundlage des FIDES. Vorab werden dazu die einzelnen Betriebszustände eines Tages definiert, welche
als Grundlage für die weiteren Berechnungen dienen. Es wird versucht, den Tagesablauf des Roboters so
präzise wie möglich zu simulieren. Anschliesend kann die Ausfallrate des Bohrmoduls in Abhängigkeit
der vom FIDES vorgegebenen Einflussfaktoren ermittelt werden. Letztlich werden die ermittelten Werte
6 1 Einleitung
der beiden Standards miteinander verglichen, sowie mögliche Grenzen und Problematiken der Standards
aufgezeigt.
Die folgende Bachelorarbeit analysiert und wertet die Messdaten eines Niederschlagsensors aus, der auf dem induktiven Wirbelstromprinzip aufbaut. Der Sensor wird an der Hochschule Ruhr West im Institut für Mess- und Sensortechnik entwickelt. Er soll nach erfolgreicher Konfiguration die Niederschlagsintensität und die Tropfengröße über die Resonanzfrequenz der Spule ausgeben können. Um dieses Ziel zu erreichen, gibt die Bachelorarbeit eine Einschätzung, inwieweit das System für eine Niederschlagserfassung geeignet ist und welche Verbesserungen vorgenommen werden können. Dazu wurden die Messdaten in einer Regenkammer der Firma Lambrecht meteo GmbH erfasst. Für die Versuche wurden zwei Flachspulen mit Resonanzfrequenzen von 1,7 MHz und 8 MHz nacheinander ausgewertet. Die resultierenden Messdaten werden sowohl im Zeit- als auch im Frequenzbereich auf Verhaltensmuster und Kennwerte untersucht. Aus den Ergebnissen geht hervor, dass der Sensor aufgrund von äußeren Einflüssen und inneren Verhaltensweisen keine signifikante Antwort auf den Niederschlag ausgibt, um die Niederschlagsintensität und die Tropfengröße zu ermitteln. Dennoch zeigt sich, dass die Resonanzfrequenz der Spulen gegensätzliche Reaktionen hervorruft. Die Spule mit der Resonanzfrequenz von 1,7 MHz reagiert deutlich unempfindlicher auf äußere Einflüsse wie parasitäre Kapazitäten. Allerdings werden nur Regentropfeneinschläge bei hohen Niederschlagsmengen deutlich erkannt. Die Spule mit der Resonanzfrequenz von 8 MHz hingegen zeigt ein empfindlicheres Verhalten auf äußere Einflüsse. Zur Optimierung des Niederschlagssensors, muss dieser konfiguriert werden, damit er äußeren Einflüssen robust entgegenwirkt und den Niederschlag sensibel genug detektiert. Zudem müssen Ausreißer, die in der Frequenzanalyse entdeckt wurden und von den inneren Verhaltensweisen stammen, entfernt werden.
Gegenstand der hier vorgestellten Arbeit ist die Optimierung der Soft- und Hardware eines induktiven Niederschlagssensors im Rahmen des Verbundforschungsprojektes KIWaSuS (KI-basiertes Warnsystem vor Starkregen und urbanen Sturzfluten). Auf Grundlage von Testergebnissen in einem Testlabor für Niederschläge ergeben sich Optimierungsansätze zur softwareseitigen Behebung von fehlerhaften Daten, eine hardwareseitige Steigerung der Qualität und der Empfindlichkeit des verwendeten induktiven Wirbelstromsensors und der Verbesserung des Wasserablaufes auf der Oberfläche des Sensorgehäuses. Zur Durchführung der Optimierung wurde empirisch das Ausführen des zugrunde liegenden Programmes auf mögliche Konflikte analysiert und angepasst, die Hardware des Sensors modifiziert und auf seine Empfindlichkeit überprüft sowie die Neigung und das Abdichtungskonzept des Gehäuses verändert und bewertet. Die Ergebnisse zeigen, dass kapazitive Anpassungen der Spule zu einer starken Stabilität des Sensors führen und eine hohe Resonanzfrequenz eine Steigerung der Empfindlichkeit hervorruft. Zusätzlich verhindert die Ausführung des Programmes auf zwei getrennten Mikrocontrollern das Auftreten fälschlicher Daten. Anpassungen des Sensorgehäuses durch die Erhöhung der Neigung und die Verwendung eines randlosen Abdichtungskonzeptes führen zu einem höheren Abfluss, aber zu keiner Eliminierung der Frequenzänderung aufgrund der Masse des aufliegenden Wassers. Die Ergebnisse zeigen, dass vor allem die Anpassungen der Software und der Spulenkonfiguration die Stabilität und Empfindlichkeit des Messsystems steigert.
In dieser Arbeit wurde eine Motorsteuerung für mikrofluidische Peristaltikpumpen in Lab-on-a-Chip Systemen entwickelt. Neben der dafür notwendigen elektrischen Schaltung wurde viel Wert auf die softwareseitige Umsetzung gelegt. Zusätzlich zu der reinen Vorgabe von essentiellen Größen, wie beispielsweise der Drehzahl und dem damit geförderten Volumen, wird ein vielseitiges und zuverlässiges Steuerungssystem vorgestellt, das versucht Schwankungen im geförderten Flüssigkeitsstrom zu reduzieren. Um schon vor dem ersten Betrieb, des parallel zu dieser Arbeit gefertigten mechanischen Aufbau, die Leistung sowie Ausmaße der Schwankungen abzuschätzen, wurde der zu erwartende Volumenstrom auf Basis der geometrischen Ausmaße modelliert. Dadurch können Algorithmen zur Glättung des Flusses bereits in einer frühen Phase der Softwareentwicklung berücksichtigt werden. Für eine bessere Charakterisierung des mechanischen Aufbaus und Überwachung des Betriebs wurde das System um eine sensorlose Erkennung von Bewegungen des Motors ergänzt. Somit kann unter anderem die Zuverlässigkeit und Dimensionierung der verwendeten Motoren überprüft werden. Zusätzlich wurde der Prozess zum Verschweißen von thermoplastischer Elastomer Folie mit dem mikrofluidischen Chip optimiert.
The highly successful lecture series on the topic of measurement and sensor technologies as part of the IEEE Workshop at the University of Applied Sciences Ruhr West (HRW) is being continued in collaboration with the University of Siegen, the TU Chemnitz and the ITMO National Research University of Information Technologies, Mechanics and Optics in St. Petersburg. This time the event is featuring an even more international orientation by linking it with the Russian SENSORICA. The topics cover industrial and medical measurement technology as well as sensor technology in vehicles. Our event offers a platform for knowledge transfer between industry and public and commercial research institutions in the area of measurement technology.
This Abstract Book offers the opportunity of contacting speakers even after the event.
In addition we are very pleased to have selected contributions published in a special edition of the journal „tm Technisches Messen“ (De Gruyter Oldenbourg Verlag) again this year.
The detection of soil erosion processes in dams, hydraulic heave failure or corrosion processes of reinforcing steel in concrete are a small selection of measuring applications in civil engineering where the impedance analysis can be used to determine the measurand. Those measuring applications are having high requirements for the measuring hardware. For example a common interface for fast data exchange, high resolution, independent functionality and easy customizability to suit the measuring application. For that reason, a well-known application for steel-mill process monitoring can be used as a development platform. This hardware platform is based on a vector network analyzer and is meeting the requirements mainly. However, a couple of modifications has to be made, like replacing the ADC for a higher sample rate, Ethernet for easy and fast data exchange and the microcontroller for more calculation power.
Process Monitoring in Steel-Mills using Impedance Analysis: VNA Improvement for Data Acquisition
(2017)
The process automation extends over every manufacturing step of a product in the steel-mill to increase the quality, quantity and energy efficiency. The product dimensions are an important part of the quality control; these must maintain the specified tolerances. Additional to the cross-sectional-area, the measured data contains much more information about the manufacturing process, e.g. eccentricity, condition of the rolls and defects of the rod. For analyzing the measured data and to gather more information about the manufacturing process it is necessary to increase the speed of the data acquisition by performing some modifications of the VNA, e.g. faster analog to digital converter and microcontroller, improved firmware and optimized values of the passive electrical components for faster time constants and transient responses.
Rolling mills are continually improved and opti-mized by implementing innovative technology to decrease costs and scrap. Despite of the progressive automation and experience, some important process parameters can still not be determined with sufficient accuracy. As part of the research project PIREF, the velocity of the hot rolled rod shall be measured by using im-pedance analysis to estimate the volumetric flow rate of the mate-rial. For a high accuracy measurement of the impedance, a pow-erful VNA is used. To minimize errors in the measurement, caused by e.g. temperature drift, a correction of the measurement fre-quency is needed. This must be achieved without recalibration of the VNA to avoid faulty behavior of the online control. To solve this problem, an approach based on a polynomial regression is presented in this work.
Quality and dimensional accuracy of hot rolled steel rods depend on several process parameters. In fact many of these crucial parameters are not be sufficiently determined yet. By improving automation and process control costs and scrap of production can be decreased. As part of the research project PIREF, one of these parameters – the roll gap – is under investigation beside other topics. Before starting rolling, the roll gap is typically set to a fixed value according to the planed dimensions of the product, but the forces during the rolling of the rod cause an enlargement of the roll gap. In which way the rolls change their position and form shall be examined in our research project. Therefore a first experimental setup has been built up to determine the change in position of the rolls under applied force. This is realized by a pot core coil as sensor using impedance analysis. The first results are presented in this work as a proof-of-principle.
Process diagnosis is an important method for improving product quality in rolling mills. In addition, the measurement of process variables such as roll gap, cross-sectional area, velocity, and volume flow of the material during production enables the implementation of model-based control concepts to improve product quality. The non-contact speed measurement of hot wire and bar is still a big challenge due to the rough environmental conditions and is solved mainly with optical measuring methods in production. The alternative measurement principle with eddy current sensors presented in this paper enables velocity measurement at locations in a rolling mill where optical measurement methods are not suitable.
In the field of producing hot-rolled steel bars and wires, hot rolling mills are incomplete or barely equipped with measuring technology for recording relevant process parameters. Therefore, there is a big potential to increase product quality and to decrease costs and scrap by improving process control establishing new sensor systems. One of these crucial parameters is the roll gap,which is investigated as part of the research project PIREF. In this paper an experimental setup for examining the roll gap during a rolling process is presented and based on these results different sensor arrangements are discussed.
Velocity Approximation of Hot Steel Rods Using Frequency Spectroscopy of the Cross-Section Area
(2019)
In this work, an approach for velocity approximation of hot steel rods based on frequency spectroscopy is presented. For this purpose, a sensor already implemented in a rolling mill for measuring the cross-sectional area of the rolling stock is used to obtain information about the velocity of the hot rods. Moreover, the effect of forward slip is briefly discussed.
The development of innovative measuring technology for process optimization in hot rolling mills becomes more and more relevant because of increasing demands on product quality. Measurement technology for high-resolution non-contact cross-sectional area measurement has shown that the variation in cross-sectional area contains information about the rolling process. This information can be used for the development of new measurement devices and analytical methods for process optimization. The harsh environmental conditions and strict safety regulations result in great effort when implementing a new sensor prototype in hot rolling mills. For this reason, this work presents a mechatronic test stand that can simulate the cross-sectional area variation under laboratory conditions realistically.
Mobile Walzenmesstechnik
(2003)
Magnetisch-induktive Techniken finden seit langer Zeit viele Anwendungsfelder in der Medizin, Sicherheitstechnik und der Industrie. Obwohl die technischen Grundlagen seit vielen Jahrzehnten bekannt sind, werden auf Basis detaillierter Analysen spezielle Lösungsansätze verfolgt, die neuartiges Anwendungspotential erschließen sollen. Dazu dienen verbesserte Werkzeuge wie Computersimulationen und analytische Berechnungen sowie neu kombinierte Methoden und Aufbauten aus Leistungselektronik und Signaldetektion. Die Vorteile magnetisch-induktiver Techniken sind dabei u.a., dass sie das Prüfobjekt nicht schädigen, berührungslos arbeiten, robust gegenüber Verschmutzungen und einfach im Aufbau sind. Ein Nachteil dieser Technik ist die unzureichende Auflösung von feinen Strukturen. In der aktuellen Forschung und Entwicklung werden unterschiedliche Spulenanordnungen zur Anwendung in industriellen und medizinischen Fragestellungen untersucht und optimiert. Thema dieser Arbeit ist es, durch Verbesserung der Spuleneigenschaften, neue Anwendungsbereiche für die zerstörungsfreie Materialprüfung zu erschließen. Es wird eine Methode vorgestellt, die Eigenschaften magnetisch-induktiver Tastspulen zu verbessern und so den Aufwand bei der Signalverarbeitung zur Rekonstruktion im Rechner zu reduzieren sowie die Auflösung zu erhöhen. Dazu werden zwei Spulenanordnungen, Transmissions -Tastspulen und Gradiometer - Tastspulen, vergleichend
gegenübergestellt und ihre technischen Grenzen aufgezeigt.
In the field of magnetic inductance tomography,
signal processing is a real challenge. This is due to the divergent
nature of magnetic fields. The sensitivity, i.e. the change in the
receiving signal by means of an electrically conductive sample
in a measuring volume depends strongly on the positioning
of the sample. Objects that are located near the transmitting
or receiving coils are very well locatable, where objects in
larger distance are hard to detect. In this paper an approach
is presented that improves the topology of the magnetic fields
in the ”magnetic induction tomography” (MIT) by changing
geometric constructions and current patterns of coils so far,
as to allow a sharper localization of objects within the space.
The aim is to level the distribution of the sensitivity in the
measuring volume, so that electrically conductive objects with
a larger distance between transmitting and receiving unit can
be detected with almost the same signal intensity as objects
close to the transmitting and receiving unit. The simulation tool
Comsolic is used for the geometric modeling making a finite
element analysis (FEA). The subsequent signal processing and
analysis of the simulation results are implemented in Matlabic .
Within this FEA the coil geometries and current patterns are
changed numerically, so that the minimum object size, that is
still detectable, is, compared to the known MIT, reduced and the
sensitivity of the system is improved. To validate the simulation in
Comsolic , first simulation results are compared with analytical
models and analyses.
Methods of red-hot rod shape testing require a robust non-contact measurement principle as a touch point could lead to damages to the rod and the detection unit. Therefore a new basic approach based on high frequency eddy current (HFEC) has been investigated. Due to the robustness and the ability to determine the rod shape even above the Curie temperature this principle is especially well suited and can be implemented in the production process directly. The first automatic measurement setup was successfully developed with promising results. Hereby a defect of ovality was detected with a parallel RLC-oscillator. The capacity of this RLC-oscillator is constant whereas the inductance is the measurement part that varies due to eddy current interactions with the rod.
Fat content of liver is an essential parameter to decide whether a liver is suitable for transplantation or not. The determination of fat content is often challenging and usually there is not enough time to bring a specimen to a pathologic laboratory. That is why transplantation clinics need a technique to measure the fat content of a graft. In this paper the theoretical basics and an existing laboratory setup are presented.
The harmonic and interharmonic analysis recommendations are contained in the latest International Electrotechnical Commission (IEC) standards on power quality. Measurement and analysis experiences have shown that great difficulties arise in the interharmonics detection and measurement with acceptable levels of accuracy. In this paper, the spectral leakage problems of the discrete Fourier transform due to synchronization errors of interharmonics are analyzed. The time-domain averaging is investigated for the processing of harmonics in the framework of the IEC standards. A difference filter is proposed to detect interharmonics and can be compatible with the IEC standards. Simulations and the field results show the usefulness of the proposed methods.
The transurethral resection (TUR) is a standard technique in urological treatment procedures. Both, monopolar and bipolar electrosurgical systems, are used for TUR. Whereas electrical and physical processes in surgery surroundings are well understood for monopolar systems, there is no sufficient data base for the assessment of the processes with the use of bipolar systems. In this context a multi-electrode measuring system was developed to visualize the spatial potential distribution around bipolar electrosurgical devices as a first step to risk analysis. To simulate the anatomic surroundings of a transurethral surgery a cylinder filled with isotonic saline solution was used as a complexity reduced experimental environment.
The bipolar transurethral resection is a further development of monopolar transurethral resection, being the gold standard in surgical treatment of prostate and bladder diseases. To create the metrological basis for understanding of electrical and physical processes during bipolar transurethral resection an experimental set-up to visualize spatial potential distribution around bipolar devices was developed. A hardware based signal conditioning and specific undersampling are presented as data acquisition methods for a sampling rate up to 1 MS/s. These methods are compared with the possibilities of a high speed data acquisition card. For more than four measuring channels and depending on the output bandwidth of the electrosurgical generator either hardware based signal conditioning or specific undersampling is suggested.
Bipolar electrosurgical systems are used for the treatment of benign prostatic hyperplasia (BPH) in urology. In order to analyse electrothermal processes during surgery the power loss density distribution around a bipolar resectoscope is calculated out of the measured potential distribution in isotonic saline solution ex situ. During further analysis power loss density values act as input for the Penne's bioheat equation. To achieve results, which are as realistic as possible, a method to obtain power loss density values, depending on the observed tissue or medium in the operating field, is presented. Applying this method, the power loss density distribution in isotonic saline solution at 25 °C is compared to the distribution calculated for the average conductivity of biological tissue in the region of interest.
Detection of air trapping in chronic obstructive pulmonary disease by low frequency ultrasound
(2012)
Background: Spirometry is regarded as the gold standard for the diagnosis of COPD, yet the condition is widely underdiagnosed. Therefore, additional screening methods that are easy to perform and to interpret are needed. Recently, we demonstrated that low frequency ultrasound (LFU) may be helpful for monitoring lung diseases. The objective of this study was to evaluate whether LFU can be used to detect air trapping in COPD. In addition, we evaluated the ability of LFU to detect the effects of short-acting bronchodilator medication.Methods: Seventeen patients with COPD and 9 healthy subjects were examined by body plethysmography and LFU. Ultrasound frequencies ranging from 1 to 40 kHz were transmitted to the sternum and received at the back during inspiration and expiration. The high pass frequency was determined from the inspiratory and the expiratory signals and their difference termed F. Measurements were repeated after inhalation of salbutamol.Results: We found signi ficant differences in F between COPD subjects and healthy subjects. These differences were already significant at GOLD stage 1 and increased with the severity of COPD. Sensitivity for detection of GOLD stage 1 was 83% and for GOLD stages worse than 1 it was 91%. Bronchodilator effects could not be detected reliably.Conclusions: We conclude that low frequency ultrasound is cost-effective, easy to perform and suitable for detecting air trapping. It might be useful in screening for COPD
Photoluminescence (PL) in GaN or InGaN layers monitored during epitaxial growth at high temperatures permits a quasi-continuous in situ characterization of opto-electronic properties. Therefore, epitaxial parameters can now be optimized at the earliest possible stage. A pulsed and high-power UV laser was required for PL excitation at high temperatures. Herein, the underlying nonlinear mechanism was studied via time-resolved PL experiments and rate equation-based modeling. A temperature-activated and saturable path for quenching over defects was identified. Beyond the saturation threshold, reasonably-intensive PL sets in. At high temperatures not only is the near band gap-PL present, but also—as a new observation—a defect-assisted PL emerges. Apart from these specific electronic transitions in high-temperature PL of GaN, a simple, but reasonably predictive model of the luminescent thin film has been set up to track down interference fringes in the PL spectra. It is worth mentioning that the spectral PL modulation (aiming at the Purcell effect) is often mixed up with ordinary Fabry–Pérot interference. A distinction has become key to properly analyze the spectral signatures of high-temperature PL in order to provide a reliable in situ characterization of GaN layers during epitaxial growth
Untersuchung des Einflusses von Längsrissen in Drähten auf die Impedanz eines Wirbelstromsensors
(2012)
Induktive Bioimpedanzmessung – Verbesserte örtliche Auflösung durch geeignete Spulengeometrien
(2013)
Influencing Parameters on Measuring the Cross-Section Area of Hot Rolled Rods in Steel Industries
(2014)
Die transurethrale Resektion der Prostata (TURP) ist ein Verfahren der Elektrochirurgie innerhalb der Urologie. Thema der Arbeit ist die Entwicklung einer Methodik für realitätsnahe vergleichende Untersuchungen der elektrothermischen Vorgänge um Resektoskope zur bipolaren TURP. Die Relevanz dieses Themas liegt in der aktuellen Diskussion, ob elektrothermische Verletzungen eine mögliche Ursache urethraler Komplikationen darstellen. In diesem Kontext sind nicht die Vorgänge an der Resektionselektrode sondern in nicht behandelten Arealen des Operationsgebiets von Interesse. Bisher durchgeführte Untersuchungen konzentrieren sich auf monopolare Systeme. Untersuchte bipolare Elektrodenanordnungen unterscheiden sich allerdings von heutigen bipolaren Resektoskopen. Die vorhandenen Erkenntnisse sind deshalb nur äußerst eingeschränkt anwendbar. Informationen zu thermischen Vorgängen bezüglich Spätkomplikationen liegen nicht vor.
Der gewählte Ansatz aus messtechnischer Bestimmung der 3D Potentialverteilung ex situ sowie modellbasierter und numerischer Analyse der sich daraus ergebenden 3D Verlustleistungsdichteverteilung und der darauf beruhenden Temperaturberechnung im operationsnahen Gewebe ermöglicht ein auf die Realität übertragbares Ergebnis. Die berechnete Temperatur dient des Weiteren als Grundlage einer medizinischen Einschätzung hinsichtlich des Potentials elektrothermischer Verletzungen. Ergebnis der Arbeit ist, dass vergleichende Untersuchungen bipolarer Resektoskope mit der entwickelten Methodik durchführbar sind. Für die untersuchte bipolare Elektrodenanordnung erscheinen elektrothermische Verletzungen als Ursache urethraler Strikturen bei konservativer Betrachtung und unter durchschnittlichen Operationsbedingungen ohne intraoperative Komplikationen unwahrscheinlich.
This experimental study demonstrates for the first time a solid-state circuitry and design for a simple compact copper coil (without an additional bulky permanent magnet or bulky electromagnet) as a contactless electromagnetic acoustic transducer (EMAT) for pulse echo operation at MHz frequencies. A pulsed ultrasound emission into a metallic test object is electromagnetically excited by
an intense MHz burst at up to 500 A through the 0.15 mm filaments of the transducer. Immediately thereafter, a smoother and quasi “DC-like” current of 100 A is applied for about 1 ms and allows an
echo detection. The ultrasonic pulse echo operation for a simple, compact, non-contacting copper coil is new. Application scenarios for compact transducer techniques include very narrow and
hostile environments, in which, e.g., quickly moving metal parts must be tested with only one, non-contacting ultrasound shot. The small transducer coil can be operated remotely with a cable
connection, separate from the much bulkier supply circuitry. Several options for more technical and fundamental progress are discussed.
Optimization of Encircling Eddy Current Sensors for Online Monitoring of Hot Rolled Round Steel Bars
(2014)
Modern manufacturing industries are continually working on quality enhancements for the hot rolling process of round products. One method for improving the finalisation of the rods is the implementation of an automatic size control system. As a result of these trends over the last few years, there has been an increasing demand for more accurate online measurements. Thus the reason for the research performed for this thesis. A particular challenge throughout this research was dealing with the temperature changes (up to 1200°C) from the in- and output of the fervent rolling stocks, and the effect this temperature changes had on the sensors. Furthermore, there is also high demand for developing fast and practical electronic measuring equipment, capable of measuring during high transport velocities (up to 120 m/s). The eddy current principle is just one of the very few methods available which can with-stand such harsh industrial environments. In fact, eddy current sensors are already being integrated into online monitoring tasks for hot rolling processes. The measurement uncertainty, however, is still considerably large for process control purposes. One reason for this lies within the ability for eddy current detectors to receive signals influenced by outward forces, i.e. forces dependent on its location, its geometry, the outside temperature and the material properties of a particular target. Thus the current accuracy for a cross-sectional area measurement, for example, is no higher than 1%. As a result, this thesis investigates the magnitude of all individual influential factors on the eddy current detectors, using model-based analysis techniques. The analytical model provides a solution for all rotationally symmetrical targets and the FEA model covers all of the other influencing parameters in a more time consuming manner. This thesis then provides different methods which are developed to separate the cross-sectional area measurement of a rod from all of the other influencing parameters. In addition, a material tracking approach for round products is developed. Two different kinds of prototypes, capable of measuring approximately 466 Tons of red-hot steel rods during the production process, are finally introduced in this thesis. The usefulness of the eddy current principle is validated by the provided field test results. The count accuracy for the identification of 2876 bars was found to be 99.93%, and the average measurement accuracy for the cross-sectional area experiments was reduced to ± 0.29 % when including all of the findings.
A Large and Quick Induction Field Scanner for Examining the Interior of Extended Objects or Humans
(2017)
This study describes the techniques and signal properties of a large, powerful, and linear-scanning 1.5 MHz induction field scanner. The mechanical system is capable of quickly reading the volume of relative large objects, e.g., a test person. The general approach mirrors Magnetic Induction Tomography (MIT), but the details differ considerably from currently-described MIT systems: the setup is asymmetrical, and it operates in gradiometric modalities, either with coaxial excitation with destructive interference or with a single excitation loop and tilted receivers. Following this approach, the primary signals were almost completely nulled, and test objects' real or imaginary imprint was obtained directly. The coaxial gradiometer appeared advantageous: exposure to strong fields was reduced due to destructive interference. Meanwhile, the signals included enhanced components at higher spatial frequencies, thereby obtaining a gradually improved capability for localization. For robust signals, the excitation field can be powered towards the rated limits of human exposure to time-varying magnetic fields. Repeated measurements assessed the important signal integrity, which is affected by the scanner´s imperfections, particularly any motions or respiratory changes in living beings during or between repeated scans. The currently achieved and overall figure of merit for artifacts was 58 dB for inanimate test objects and 44 dB for a test person. Both numbers should be understood as worst case levels: a repeated scan with intermediate breathing and drift/dislocations requires 50 seconds, whereas a single measurement (with respiratory arrest) takes only about 5 seconds.
Die steigenden Anforderungen an den Umweltschutz bei möglichst niedrigen Kosten betreffen auch die öffentlichen Kanalnetze und Kläranlagen. Speziell die Kanalnetze sind über Jahrzehnte gewachsen, ohne dass kostengünstig eine genaue Bilanz ihrer Leistungsfähigkeit bis in ihre Segmente möglich war. Es fehlte vor allem in kleineren Systemen an Messwerten für die Transportmengen in Abhängigkeit der Witterung zur Beurteilung des Transportverhaltens der Einzelsegmente. Erst diese Messwerte ermöglichen eine mathematische Modellbildung mit Parametrierung und damit Ansätze für eine Optimierung. In diesem Beitrag wird der Prototyp eines neuartigen Sensors vorgestellt, der die gleichzeitige, kostengünstige und zeitbegrenzte Erfassung der Abwasserströme an verschiedenen Punkten im Kanalnetz ermöglichen soll. Die im Abwasserstrom befindlichen Teile des Sensors sind preiswerte mechanische Komponenten, die kostengünstig und einfach zu ersetzen sind. Die Erfassung der Strömungsgeschwindigkeit und der durchströmten Querschnittsfläche erfolgt mit Hilfe der sich an einem Störkörper einstellenden Druckverhältnisse.
In modernen Prüffeldern zur Warenendkontrolle dienen halbleitergesteuerte Frequenzumformer zur Einstellung der Drehzahl. Diese Systeme verursachen erhebliche Störungen der Strom- und Spannungssignale. Aus diesen Signalen müssen alle elektrischen Kenngrößen berechnet werden. Eine besondere Bedeutung haben dabei die Frequenz und Phasenlage. In diesem Beitrag wird ein mathematischer Algorithmus vorgestellt, der zur Berechnung von Frequenz und Phasenlage bei guter Unterdrückung dieser Störungen eingesetzt werden kann.
Im vorliegenden Beitrag wird das Phasen-Differenz-Verfahren zur Frequenzmessung der durch Rauschen gestörten Signale vorgestellt. Es wird gezeigt, dass Frequenzausreißer bei Anwendungen dieses Verfahrens entstehen, auch wenn das Signal-zu-Rausch-Verhältnis ausreichend groß ist. Die Ursachen der Frequenzausreißer werden analysiert. Zur Korrektur wird ein Lösungsansatz vorgeschlagen. Im Vergleich mit anderen Verfahren kann das verbesserte Phasen-Differenz-Verfahren die Frequenz der durch Rauschen gestörten Signale mit größerer Genauigkeit und vertretbarem Rechenaufwand berechnen.
Efficient photoluminescence (PL) spectra from GaN and InGaN layers at temperatures up to 1100 K are observed with low noise floor and high dynamic resolution. A number of detailed spectral features in the PL can be directly linked to physical properties of the epitaxial grown layer. The method is suggested as an in situ monitoring tool during epitaxy of nitride LED and laser structures. Layer properties like thickness, band gap or film temperature distribution are feasible.
Electro-magnetic acoustic transducers (EMATs) are intended as non-contact and non-destructive ultrasound transducers for metallic material. The transmitted intensities from EMATS are modest, particularly at notable lift off distances. Some time ago a concept for a “coil only EMAT” was presented, without static magnetic field. In this contribution, such compact “coil only EMATs” with effective areas of 1–5 cm2 were driven to excessive power levels at MHz frequencies, using pulsed power technologies. RF induction currents of 10 kA and tens of Megawatts are applied. With increasing power the electroacoustic conversion efficiency also increases. The total effect is of second order or quadratic, therefore non-linear and progressive, and yields strong ultrasound signals up to kW/cm2 at MHz frequencies in the metal. Even at considerable lift off distances (cm) the ultrasound can be readily detected. Test materials are aluminum, ferromagnetic steel and stainless steel (non-ferromagnetic). Thereby, most metal types are represented. The technique is compared experimentally with other non-contact methods: laser pulse induced ultrasound and spark induced ultrasound, both damaging to the test object’s surface. At small lift off distances, the intensity from this EMAT concept clearly outperforms the laser pulses or heavy spark impacts.
In this work we report the first quasi-continuous in-situ photoluminescence study of growing InGaN LED structures inside an industrial-grade metal-organic vapor phase epitaxy (MOVPE) reactor at growth temperature. The photoluminescence spectra contain information about temperature, thickness and composition of the epitaxial layers. Furthermore, the in-situ spectra – even at an early stage of the growth of the active region – can be used to predict the photoluminescence emission wavelength of the structure at room temperature. In this study an accuracy of this predicted wavelength in the range of ± 1.3 nm (2σ) is demonstrated. This technique thus appears suitable for closed-loop control of the emission wavelength of InGaN LEDs already during growth.
A simple copper coil without a voluminous stationary magnet can be utilized as a non-contacting transmitter and as a detector for ultrasonic vibrations in metals. Advantages of such compact EMATs without (electro-)magnet might be: applications in critical environments (hot, narrow, presence of iron filings…), potentially superior fields (then improved ultrasound transmission and more sensitive ultrasound detection).
The induction field of an EMAT strongly influences ultrasound transduction in the nearby metal. Herein, a simplified analytical method for field description at high liftoff is presented. Within certain limitations this method reasonably describes magnetic fields (and resulting eddy currents, inductances, Lorentz forces, acoustic pressures) of even complex coil arrangements. The methods can be adapted to conventional EMATS with a separate stationary magnet.
Increased distances (liftoff) are challenging and technically relevant, and this practical question is addressed: with limited electrical power and given free space between transducer and target metal, what would be the most efficient geometry of a circular coil? Furthermore, more complex coil geometries (“butterfly coil”) with a concentrated field and relatively higher reach are briefly investigated.
Wirbelströme werden in der Mess- und Sensortechnik sehr erfolgreich benutzt, um berührungslos Risse und Abstände metallischer Halbzeuge zu bestimmen. Die Messung von Konturen ist mit diesem industrietauglichen Wirkprinzip bisher nicht realisiert worden. Hier werden häufig optische Messsysteme eingesetzt. Speziell bei glühenden Werkstücken oder bei Benetzung der Halbzeuge mit Bohremulsionen und Schneidölen steigt der Aufwand für den Einsatz optischer Systeme stark an. Messverfahren, die auf hochfrequenten Wirbelströmen basieren, sind aufgrund ihrer einfachen Aufbauten deutlich robuster und somit besser für diese Anwendung geeignet. Voruntersuchungen zeigten, dass mit dieser Methode schon kleine Geometrieabweichungen des Walzgutes von wenigen Mikrometern detektiert werden können. In diesem Beitrag werden zwei Möglichkeiten zur Messung der spektralen Impedanzbeeinflussung eines Messschwingkreises durch die Wirbelströme im Werkstück gegenübergestellt.
The production and deformation of perforated sheets introduces high levels of mechanical stress into the material. In a significant fraction, such stress levels lead to crack formation in the processed sheets. Additionally, the material might be thinned and weakened in the exposed areas; these areas tend to crack at any later dates. Currently no measuring device for the detection of such material cracks or narrowing in perforated sheet metals is in practical use. Such device should be able to test the deformed circumference of the processed sheets within the very limited time of the production cycles. This paper describes the physical principles and a metrological implementation of a potential method for fast crack detection in perforated sheet metals. Even a critical material thinning - prior to the formation of a crack - can be observed. The measuring task appears to be solvable on the basis of high frequency electromagnetic fields.
Die steigenden Anforderungen der fertigenden Industrie an Halbzeuge wie Stahl- und Aluminiumblech führen zu großen Anstrengungen bei der Entwicklung neuer und Verbesserung alter Walztechniken. Einen wesentlichen Einfluss auf die erreichbaren Flächentoleranzen der Bleche hat neben der Walzenform die Temperaturverteilung an der Walzenoberfläche.
Increasing demands from the manufacturing industry on semifinished products such as steel and aluminium plate are leading to greater efforts in the development of new and the improvement of existing rolling techniques. In addition to the shape of the roll, temperature distribution on the roll surface has a significant influence on the surface tolerances of the sheets which may be achieved.
Der Bedarf an feuerverzinkten Stahlbändern ist besonders in der Automobilindustrie sehr groß und es werden zugleich immer höhere Qualitäten gefordert. Hierbei bildet vor allem die Homogenität der Zinkschichtdicke ein entscheidendes Qualitätsmerkmal. Um das Stahlband ausreichend vor Umwelteinflüssen zu schützen, muss eine, vom Kunden spezifizierte, Mindestzinkschichtdicke aufgetragen werden. Beim hier angewandten Verzinkungsverfahren durchläuft das Band ein Zinkbad und anschließend wird das überschüssige Zink berührungs-los mittels sogenannten Abblasdüse so abgetragen, sodass eine möglichst homogene Zinkschicht erhalten bleibt. Hierzu ist es notwendig den Abstand zwischen Band und Airknife konstant zu halten. Störende Bandbewegungen führen zu inhomogene Zinkschichtdicken, welche die Qualität der Verzinkung vermindern. Diese Qualitätsverminderung und der erhöhte Zinkeinsatz soll durch geeignete Maßnahmen verringert werden. Bisher eingesetzte berührungslose Bandstabilisatoren können die Bandbewegung im Allge-meinen dämpfen, jedoch treten noch Betriebszustände auf, in denen eine inhomogene Zinkschicht sichtbar ist. Die Ursache dieser Inhomogenitäten liegt in anlagenbedingten dominanten Schwingungen des Bandes, deren Ursache zu klären ist. Im vorliegenden Beitrag wird ein Modell der Bandbewegung vorgestellt, das durch die theore-tische Modellbildung und experimentelle Identifikation erstellt worden ist. Das Modell beschreibt die Bewegung des Bandes bezüglich ausgewählter Freiheitsgrade und ermöglicht die Analyse der kritischen Betriebszustände. Darüber hinaus soll dieses Modell zur Stabilisierung des Bandes in einer modellgestützten Reglung verwendet werden.
The transurethral resection (TUR) is a standard technique in urological treatment procedures. Both, monopolar and bipolar electrosurgical systems, are used for TUR. Whereas electrical and physical processes in surgery surroundings are well understood for monopolar systems, there is no sufficient data base for the assessment of the processes with the use of bipolar systems. In this context a multi-electrode measuring system was developed to visualize the spatial potential distribution around bipolar electrosurgical devices as a first step to risk analysis. To simulate the anatomic surroundings of a transurethral surgery a cylinder filled with isotonic saline solution is used as a complexity reduced experimental environment. Investigations about time stability and a qualitative assessment of the experimental set-up show deviations of measured values less than 5%. This is sufficient for further analysis of calculated power loss density distributions based on measured potential distributions. The spatial potential distribution around a bipolar devices is presented by horizontal and vertical sections through the experimental environment.
Die transurethrale Resektion der Prostata (TUR-P) ist der Gold Standard für die endoskopisch-chirurgische Behandlung der Benignen Prostatahyperplasie (BPH). Unbekannt ist jedoch, ob bei der bipolaren TUR-P die Möglichkeit von elektrothermischen Verletzung von benachbartem nichtopertiertem Gewebe besteht. Grund hierfür könnten höhere Ausgangsleistungen der Chirurgie-Generatoren sein. Deshalb werden experimentell gemessene Werte der räumlichen Verlustleistungsdichte um ein bipolares Resektoskop als Quellterm für die Berechnung der Temperaturänderung im operationsnahen Gewebe verwendet. Die Temperaturberechnung basiert auf der numerischen Lösung der Wärmeleitungsgleichung nach Penne. Für die gewählten Randbedingungen und Eingabeparameter sind keine signifikanten Temperaturerhöhungen im Berechnungsgebiet am proximalen Ende des Resektoskop-Schaftes festzustellen. Um ein umfassendes Verständnis zu gewinnen sollen weiterführende Untersuchungen mit einer Variation der Randbedingungen und Eingabeparameter durchgeführt werden
In dieser Veröffentlichung wird ein Konzept vorgestellt, das es erlaubt die Topologie der Magnetfelder bei der „Magnetischen Induktionstomografie“ (MIT) durch geometrische Spulenkonstruktionen und Bestromungsmuster soweit zu verändern, um eine scharfe Lokalisierung von Objekten innerhalb des Raumes zu ermöglichen. Ziel ist dabei, die Empfindlichkeit im Messvolumen gleichmäßiger als in der bekannten MIT zu verteilen, sodass elektrisch leitfähige Objekte mit größerer Entfernung zwischen Sender- und Empfängereinheit mit nahezu gleich hoher Signalintensität detektiert werden können, wie Objekte in Sender- und Empfängernähe. Dabei soll die maximale Objektgröße, die noch zu detektieren ist, verkleinert und die Empfindlichkeit des Systems verbessert werden.
To analyze the electric field around bipolar resectoscopes, used in urology, in terms of reasons for late complications after a surgical treatment a flexible multielectrode system was developed to measure the 3-D potential distribution. A high spatial resolution is achieved with the least possible individual measurements under the conditions of a quasi-static electric field. A flexible arrangement and positioning of the measuring points in the vertical direction of the experimental environment enable an adjustable spatial resolution and the selection of the region of interest. The existing influence of the multielectrode system on the measuring results is described and a correction method is presented to achieve significant results. Thus, the multielectrode system is usable for a comparative study of bipolar resectoscopes varying in the arrangement of resection and return electrode.
LEDs gelten als umweltfreundliche Beleuchtungstechnik. Für die Massenanwendung arbeiten die LED-Hersteller an einer Senkung der Kosten bzw. einer Erhöhung der Ausbeute, insbesondere bei der aufwendigen LED-Kristallbeschichtung auf den Wafern. Während der Beschichtung (MOCVD) werden optische In-situ-Messgeräte zur Überwachung des Prozesses genutzt. Die hier vorgestellte Untersuchung beschäftigt sich mit dem Einfluss von Super-Photolumineszenz-Effekten bei einer möglichen In-situ-Prozesskontrolle in der MOCVD.
Wirbelstromsensoren sind in der industriellen Messtechnik stark verbreitet. Insbesondere bei der Herstellung warmgewalzter Halbzeuge können sie durch ihre Robustheit gegenüber Wasserdampf und hohen Walzguttemperaturen überzeugen. Ein noch offenes Feld ist die In-Situ‐Detektion von Rissen im Draht während des Walzprozesses bei Walzgeschwindigkeiten bis zu 100 m/s und Materialtemperaturen bis zu 1200 ℃. Im Folgenden soll mittels der Finiten-Elemente-Analyse untersucht werden, wie sich Längsrisse im Draht auf Oberflächenströme und damit auf deren magnetische Flussdichte auswirken. Ziel ist es, Aussagen über den Einfluss verschiedener Rissbreiten und Risstiefen auf die magnetische Flussdichte zu machen und so einen möglichen Effekt auf einen Wirbelstromsensor untersuchen zu können.
Gallium Nitride (GaN) and Indium Gallium Nitride (InGaN) have become important semiconductor materials for the LED lighting industry. Recently, a photoluminescence (PL) technique for direct in-situ characterization of GaN and InGaN layers during epitaxial growth in a planetary metalorganic vapor phase epitaxy (MOVPE) reactor was reported. The PL signals reveal – at the earliest possible stage – information about current layer thickness, temperature, composition, surface roughness, and self-absorption. Thus, the PL data is valuable for both controlling and optimizing the growth parameters, thereby promising both better devices and a better yield for the LED industry. This technical report describes an extension of this PL technique to close coupled showerhead (CCS) reactors with narrow optical viewports. In contrast to the wide aperture optics in previous investigations, a compact and all-fiber optical probe without voluminous lens optics, filter elements or beam splitters was used.
Photolumineszenz (PL) aus Halbleiterstrukturen liefert Informationen bezüglich verschiedener Materialparameter wie z.B. Bandlücke, Schichtdicke sowie Temperatur. PL-Messungen werden klassischerweise erst ex situ und somit nach dem Produktionsprozess vorgenommen. Wird eine derartige PL-Messung während der Epitaxie einer Halbleiterstruktur und den damit verbundenen hohen Wachstumstemperaturen durchgeführt, erlaubt dies eine quasi-kontinuierliche In-situ-Charakterisierung der optoelektronischen Eigenschaften dieser Struktur zum frühestmöglichen Zeitpunkt, also noch in der Produktionsphase. Hierdurch wird eine In-situ-Optimierung der Prozessparameter ermöglicht, welche bei einer Ex-situ-Messung nicht gegeben ist. Die vorliegende Arbeit beschreibt zunächst theoretisch und dann anhand praktischer Messungen an industrienahen Epitaxie-Anlagen erstmals eine quasi-kontinuierliche In-situ-PL-Messung am Beispiel von wachsenden Nitrid-Halbleiterstrukturen. Über zeitaufgelöste PL-Messungen wird ein temperaturabhängiger Quenching-Mechanismus bei Gallium-Nitrid (GaN) und Indium-Gallium-Nitrid (InGaN) aufgezeigt, welcher den Einsatz von gepulsten Lasern als PL-Anregungsquelle bei hohen Wachstumstemperaturen einer Epitaxie erforderlich macht. Mit In-situ-PL-Messungen können hierdurch erstmals verschiedene Parameter einer gerade wachsenden Halbleiterschicht charakterisiert werden. Neben der Bestimmung der Temperatur und der Schichtdicke einer wachsenden, auf InGaN basierten LED-Struktur wird auch die Möglichkeit demonstriert, in einem frühen Stadium des Wachstums einer LED-Struktur ihre spätere Emissionswellenlänge bei Raumtemperatur vorherzusagen, und dies mit einer Genauigkeit von ± 1,3 nm (2σ). Diese Arbeit zeigt somit neben den industriell etablierten Messtechniken, wie z.B. pyrometrische Verfahren, eine weitere Möglichkeit zur Prozessüberwachung einer Epitaxie auf.
Editorial
Jörg Himmel, Olfa Kanoun, Thomas Seeger, Klaus Thelen IEEE Workshop on Industrial and Medical Measurement and Sensor Technology – SENSORICA 2016 1
Beiträge Jan Taro Svejda, Andreas Rennings, Daniel Erni A metamaterial based dual-resonant coil element for combined sodium/hydrogen MRI at 7 Tesla 2
Fabian Feldhaus, Ingo Schmitz, Thomas Seeger Emission spectroscopy based sensor developed for engine testing 13
Anne-Sophie Rother, Thomas Dietz, Peter Kohns, Georg Ankerhold Molecular laser-induced breakdown spectroscopy for elemental analysis 23
Johannes Kiefer, Andreas Bösmann, Peter Wasserscheid Quantitative measurement of complex substances dissolved in an ionic liquid using IR spectroscopy and chemometrics 32
Oliver Gieseler, Hubert Roth, Jürgen Wahrburg Methods to determine the scaling factor in X-ray images for exact preoperative planning in hip surgery 38
Erwin Gerz, Matthias Mende, Hubert Roth Development of an optical tracking system for a novel flexible and soft manipulator with controllable stiffness for minimal invasive surgery (MIS) 47
Jens Weidenmüller, Christian Walk, Özgü Dogan, Pierre Gembaczka, Alexander Stanitzki, Michael Görtz Telemetric multi-sensor system for medical applications – The approach 53
Inga-Maria Eichentopf, Martin Reufer Measurement and analysis of wavefront structures of diode lasers 59