Refine
Year of publication
Document Type
- Bachelor Thesis (21)
- Article (8)
- Master's Thesis (6)
- Book (3)
- Conference Proceeding (2)
- Doctoral Thesis (1)
Has Fulltext
- yes (41) (remove)
Is part of the Bibliography
- no (41)
Keywords
- GaN (1)
- Gallium (1)
- InGaN (1)
- Indium (1)
- LED (1)
- Licht emittierende Dioden (1)
- MOVPE (1)
- Nitrid (1)
- Photolumineszenz (1)
- Prozesscharakterisierung (1)
Institute
- Fachbereich 4 - Institut Mess- und Senstortechnik (41) (remove)
A Large and Quick Induction Field Scanner for Examining the Interior of Extended Objects or Humans
(2017)
This study describes the techniques and signal properties of a large, powerful, and linear-scanning 1.5 MHz induction field scanner. The mechanical system is capable of quickly reading the volume of relative large objects, e.g., a test person. The general approach mirrors Magnetic Induction Tomography (MIT), but the details differ considerably from currently-described MIT systems: the setup is asymmetrical, and it operates in gradiometric modalities, either with coaxial excitation with destructive interference or with a single excitation loop and tilted receivers. Following this approach, the primary signals were almost completely nulled, and test objects' real or imaginary imprint was obtained directly. The coaxial gradiometer appeared advantageous: exposure to strong fields was reduced due to destructive interference. Meanwhile, the signals included enhanced components at higher spatial frequencies, thereby obtaining a gradually improved capability for localization. For robust signals, the excitation field can be powered towards the rated limits of human exposure to time-varying magnetic fields. Repeated measurements assessed the important signal integrity, which is affected by the scanner´s imperfections, particularly any motions or respiratory changes in living beings during or between repeated scans. The currently achieved and overall figure of merit for artifacts was 58 dB for inanimate test objects and 44 dB for a test person. Both numbers should be understood as worst case levels: a repeated scan with intermediate breathing and drift/dislocations requires 50 seconds, whereas a single measurement (with respiratory arrest) takes only about 5 seconds.
Diese Arbeit konzentriert sich auf die Erstellung einer umfassenden technischen Dokumentation für ein Medizinprodukt der Klasse IIa gemäß den Anforderungen der Medical Device Regulation (MDR) 2017/745. Das Hauptziel besteht darin, eine konforme Dokumentation zu entwickeln, die alle wesentlichen Aspekte der Produktentwicklung, Herstellung und Verwendung abdeckt. Besonderes Augenmerk wird darauf gelegt, die regulatorischen Anforderungen der MDR zu erfüllen, um die Sicherheit und Wirksamkeit des Produkts zu gewährleisten und eine Zulassung für den europäischen Markt zu ermöglichen. Die verschiedenen Bestandteile der technischen Dokumentation, einschließlich klinischer Bewertungen, Risikomanagement, Validierungstests, Konformitätsbewertungen und Kennzeichnung, werden gründlich untersucht. Es wird eine systematische und strukturierte Herangehensweise präsentiert, um eine erfolgreiche Konformitätsbewertung für das hier beschriebene Medizinprodukt der Klasse IIa zu erreichen. Die Ergebnisse dieser Arbeit tragen dazu bei, die Qualität und Sicherheit des hier bearbeiteten Medizinproduktes der Klasse IIa zu verbessern und somit die Patientensicherheit zu gewährleisten.
Photoluminescence (PL) in GaN or InGaN layers monitored during epitaxial growth at high temperatures permits a quasi-continuous in situ characterization of opto-electronic properties. Therefore, epitaxial parameters can now be optimized at the earliest possible stage. A pulsed and high-power UV laser was required for PL excitation at high temperatures. Herein, the underlying nonlinear mechanism was studied via time-resolved PL experiments and rate equation-based modeling. A temperature-activated and saturable path for quenching over defects was identified. Beyond the saturation threshold, reasonably-intensive PL sets in. At high temperatures not only is the near band gap-PL present, but also—as a new observation—a defect-assisted PL emerges. Apart from these specific electronic transitions in high-temperature PL of GaN, a simple, but reasonably predictive model of the luminescent thin film has been set up to track down interference fringes in the PL spectra. It is worth mentioning that the spectral PL modulation (aiming at the Purcell effect) is often mixed up with ordinary Fabry–Pérot interference. A distinction has become key to properly analyze the spectral signatures of high-temperature PL in order to provide a reliable in situ characterization of GaN layers during epitaxial growth
In dieser Arbeit wurde eine Motorsteuerung für mikrofluidische Peristaltikpumpen in Lab-on-a-Chip Systemen entwickelt. Neben der dafür notwendigen elektrischen Schaltung wurde viel Wert auf die softwareseitige Umsetzung gelegt. Zusätzlich zu der reinen Vorgabe von essentiellen Größen, wie beispielsweise der Drehzahl und dem damit geförderten Volumen, wird ein vielseitiges und zuverlässiges Steuerungssystem vorgestellt, das versucht Schwankungen im geförderten Flüssigkeitsstrom zu reduzieren. Um schon vor dem ersten Betrieb, des parallel zu dieser Arbeit gefertigten mechanischen Aufbau, die Leistung sowie Ausmaße der Schwankungen abzuschätzen, wurde der zu erwartende Volumenstrom auf Basis der geometrischen Ausmaße modelliert. Dadurch können Algorithmen zur Glättung des Flusses bereits in einer frühen Phase der Softwareentwicklung berücksichtigt werden. Für eine bessere Charakterisierung des mechanischen Aufbaus und Überwachung des Betriebs wurde das System um eine sensorlose Erkennung von Bewegungen des Motors ergänzt. Somit kann unter anderem die Zuverlässigkeit und Dimensionierung der verwendeten Motoren überprüft werden. Zusätzlich wurde der Prozess zum Verschweißen von thermoplastischer Elastomer Folie mit dem mikrofluidischen Chip optimiert.
In der modernen Medizintechnik ist die zuverlässige Funktionsweise von Geräten von entscheidender Bedeutung. Diese Bachelorarbeit befasst sich mit dem Zustandsmonitoring von medizinischen Geräten, um die verschiedenen Zustände von medizinischen Geräte zu erfassen.
Das Monitoring hilft dabei, die tatsächliche Nutzungsfrequenz der Geräte zu ermitteln. Ein verbessertes Verständnis der Gerätenutzung kann dazu beitragen, Kosten zu senken und das Gerätemanagement in Krankenhäusern zu optimieren.
Das primäre Ziel dieser Arbeit war die Entwicklung einer Datenverarbeitungsmethode für das Zustandsmonitoring von Medizingeräten mittels energiesparender Funk-Sensoren. Oftmals werden in Krankenhäusern mehr Geräte angeschafft als benötigt, und dennoch müssen alle Geräte gewartet werden, selbst wenn einige selten in Betrieb sind. Dies resultiert in unnötigen Kosten und Ausfallzeiten.
Für die Untersuchung wurde ein energiesparender Funksensor eingesetzt, der mit einem Stromsensor ausgestattet ist. Dieser erfasst den Stromfluss der angeschlossenen Geräte und kommuniziert online über das IoT. Die erfassten Daten wurden komprimiert und an das TTN (The Things Network) übertragen. Ein KI-Modell wurde mit den gesammelten Daten trainiert, um die verschiedenen Zustände der Geräte zu erkennen.
Die wichtigsten Ergebnisse zeigen, dass die Zustände der Geräte variieren und typischerweise in "AN", "AUS", "Idle-Modus" und "Im Betrieb" kategorisiert werden können. Sobald der Stromfluss einen bestimmten Wert erreicht, kann die KI bestimmen, in welchem Zustand sich das Gerät befindet. Dies bietet eine wertvolle Grundlage für ein verbessertes Management und Wartungssystem in Krankenhäusern.
Detection of air trapping in chronic obstructive pulmonary disease by low frequency ultrasound
(2012)
Background: Spirometry is regarded as the gold standard for the diagnosis of COPD, yet the condition is widely underdiagnosed. Therefore, additional screening methods that are easy to perform and to interpret are needed. Recently, we demonstrated that low frequency ultrasound (LFU) may be helpful for monitoring lung diseases. The objective of this study was to evaluate whether LFU can be used to detect air trapping in COPD. In addition, we evaluated the ability of LFU to detect the effects of short-acting bronchodilator medication.Methods: Seventeen patients with COPD and 9 healthy subjects were examined by body plethysmography and LFU. Ultrasound frequencies ranging from 1 to 40 kHz were transmitted to the sternum and received at the back during inspiration and expiration. The high pass frequency was determined from the inspiratory and the expiratory signals and their difference termed F. Measurements were repeated after inhalation of salbutamol.Results: We found signi ficant differences in F between COPD subjects and healthy subjects. These differences were already significant at GOLD stage 1 and increased with the severity of COPD. Sensitivity for detection of GOLD stage 1 was 83% and for GOLD stages worse than 1 it was 91%. Bronchodilator effects could not be detected reliably.Conclusions: We conclude that low frequency ultrasound is cost-effective, easy to perform and suitable for detecting air trapping. It might be useful in screening for COPD
In this scientific research, an innovative sensor system is developed to prevent child heatstrokes in vehicles. The system incorporates a 24 GHz Continuous-Wave (CW) radar system, which identifies vital signs of an infant through a 4-by-1 patch antenna array embedded in a specifically designed circuit board. Intelligent signal processing algorithms analyze data generated by the radar chip and execute processing tasks on a robust microcontroller. The child’s respiration
rate can be extracted qualitatively from the data in nearly real-time, enabling the system to differentiate between a child and a mere shopping bag on the seat. In the event of identifying a critical condition, the system transmits this information via a data bus to a central ECU within the vehicle. This ECU is integrated with GSM and GPS connections, allowing communication with the driver or emergency services. The development of the sensor system adheres to existing
automotive industry standards, featuring a cost-effective design intended as a prototype for large-scale production. Through rigorous evaluation across various scenarios, including realworld
situations with children, the sensor system is refined. The continuously reliable function of the developed radar-based sensor system holds the potential to save children’s lives, making
a major contribution to automotive safety.
Im Rahmen der vorliegenden Bachelorarbeit in Kooperation mit der Hospitaltechnik Planungsgesellschaft mbH wurden die möglichen Effekte eines verteilten Alarmsystems von Dräger und tetronik auf die Arbeitsqualität der Pflegekräfte auf Intensivstationen untersucht.
Dazu wurde eine Online-Befragung via Microsoft Forms mit den Intensivpflegekräften der Karl-Hansen-Klinik in Bad Lippspringe und der Spezialklinik Jugenheim in Jugenheim durchgeführt. Hierbei besitzt die Intensivstation Bad Lippspringe das verteilte Alarmsystem der
Unternehmen Dräger und tetronik, wohingegen die Intensivstation Jugenheim keins besitzt. Mit Hilfe selbstständig durchgeführter Interviews wurden sowohl die befragten Intensivstationen in
ihrem Aufbau dargestellt als auch das verteilte Alarmsystem in seiner Beschaffenheit und Funktion vollständig erläutert. Die Daten aus der Online-Befragung wurden mit Hilfe eines einseitigen Zweistichproben t-Tests ungleicher Varianzen ausgewertet.
Die Auswertung der Online-Befragung ergab acht signifikante Ergebnisse, die auf eine bessere Arbeitsqualität in der Intensivstation mit dem verteilten Alarmsystems von Dräger und tetronik hinweisen. Jedoch fiel die Mehrheit der 25 Mittelwertsunterschiede nicht signifikant aus.
Schlussfolgernd ist davon auszugehen, dass der positive Effekt eines verteilten Alarmsystems auf Intensivstationen noch nicht zu genüge erreicht ist. Es ist daher anzustreben, dass das verteilte Alarmsystem weiterhin verbessert wird, sodass auch die restlichen untersuchten
Effekte signifikant werden.
Entwicklung einer Simulationsumgebung zur Ermittlung der Verluste Moderner Leistungstransistoren
(2023)
In dieser Bachelorarbeit liegt der Fokus auf der Simulation von Leistungselektronikkomponenten, wobei insbesondere MOSFETs und IGBTs im Mittelpunkt stehen. Der Verwendung von modernen Leistungshalbleiterbauteilen in elektrischen Schaltungen kommt eine immer größere Bedeutung zu, da sie die Effizienz und Leistungsfähigkeit von Energiewandlern und Invertern maßgeblich beeinflussen. Um ihre Funktionalität und Leistung unter verschiedenen Bedingungen zu verstehen und optimieren zu können, ist die Simulation ein unverzichtbares Werkzeug.
Ein wesentlicher Schwerpunkt liegt auf dem Vergleich zwischen Silizium (SI) und Siliziumkarbid (SiC) MOSFETs in einem Halbbrücken-Inverter. Hierbei werden Simulationen unter verschiedenen Temperaturen durchgeführt, um die Auswirkungen von Temperaturschwankungen auf das Verhalten dieser Transistoren zu untersuchen. Die Ergebnisse ermöglichen Einblicke in die Leistungsfähigkeit und Vor- und Nachteile der beiden Materialien in unterschiedlichen Anwendungen.
Des Weiteren wird die Simulation eines IGBTs (Insulated Gate Bipolar Transistor) eingehend untersucht. Dies umfasst die Analyse seiner elektrischen Eigenschaften sowie die Simulation und Darstellung der Einschaltverluste (EON) und Ausschaltverluste (EOFF). Die Simulationen werden mithilfe von LTspice durchgeführt, und die Verluste werden numerisch in MATLAB integriert. Diese Untersuchungen tragen dazu bei, das Verhalten von IGBTs in Schaltungen besser zu verstehen und tragen zur Optimierung von Leistungselektroniksystemen bei.
Die vorliegende Arbeit bietet somit einen umfassenden Einblick in die Simulation und Analyse von Leistungselektronikkomponenten unter verschiedenen Bedingungen und trägt zur Entwicklung effizienterer und zuverlässigerer elektrischer Schaltungen bei.
Ziel dieser Arbeit ist es, ein grundlegendes Verständnis eines elektrisch betriebenen Lenksystems zu schaffen und dessen zugehörige Anforderungen und Analysen seitens der funktionalen Sicherheit darzustellen. Beginnend mit der theoretischen Darstellung des Lenksystems und den Normen wird im praktischen Teil der Arbeit diese Theorie angewandt. Zudem werden Autonomiestufen und deren rechtliche Grundlage in Deutschland aufgeführt und diskutiert.
Hierbei wird auf die Norm für die funktionale Sicherheit, die ISO 26262 und auf die Norm für die Sicherheit der Funktion, die ISO 21448 eingegangen. Es wird erläutert, welchen Zweck die Anwendung der ISO 26262 hat und wie sie aufgrund der zunehmenden Komplexität in der Automobilbranche durch die ISO 21448 (SOTIF) ergänzt wird. Dazu wird herausgearbeitet, wann die ISO 26262 an ihre Grenzen stößt und wie unabdingbar die Anwendung von SOTIF wird.
Einhergehend mit der technologischen Entwicklung und der zunehmenden Komplexität treten nämlich vermehrt Aspekte auf, die mit der ISO 26262 allein nicht abgedeckt werden können. Sicherheitsaspekte nehmen zu und verändern sich mit neuen Komfort- und Assistenzsystemen kontinuierlich. Daher ist es auf-grund der sich ändernden Technologien und derer Komplexität unabdingbar, bestehende Ansätze zu verbessern und zusätzliche neue Methoden für die Sicherheit des Endproduktes zu entwickeln und neben den etablierten Methoden anzuwenden.
Welchen Einfluss dies auf ein modernes Lenksystem hat und wie in diesem Zusammenhang das Zusammenspiel der ISO 26262 und ISO 21448 mit klassischen Methoden wie der Fehlermöglichkeits- und Einflussanalyse (FMEA) betrachtet werden muss, wird in dieser Arbeit dargestellt. Automobilhersteller sind heute bereits in der Lage Fahrzeuge automatisiert in bestimmten Betriebsgrenzen und Bereichen fahren zu lassen. Doch was muss getan werden, um sämtliche Betriebsgrenzen aufzuheben und ein Fahrzeug „autonom“ zu gestalten? Regulatorien, Standards und Richtlinien sind bereits heute auf dem besten Weg dorthin, doch ist es in der Praxis tatsächlich realisierbar?
In dieser Arbeit wird die Thematik Datenvisualisierung von Wissensgraphen behandelt. Durch den massiven Datenbestand in der heutigen Zeit und der immer stärker werdenden Digitalisierung ist die Notwendigkeit gestiegen, aus Daten effizient Wissen generieren zu können. Folglich wurde repräsentativ eine Graphbibliothek ausgewählt, um die Daten zu visualisieren. Umgesetzt wurde die Programmierung durch ein JavaScript Framework. Die Daten einer Wissensdatenbank wurden vom Betreuer bereitgestellt. Das übergeordnete Ziel der Arbeit ist eine verbesserte Darstellung von Wissensdaten in Form eines Wissensgraphen. Sinn und Zweck dahinter ist es, Beziehungen zwischen Daten verbessert erkennen zu können und gleichzeitig Informationen zu gewinnen, die auf den ersten Blick nicht sofort erkennbar sind.
This experimental study demonstrates for the first time a solid-state circuitry and design for a simple compact copper coil (without an additional bulky permanent magnet or bulky electromagnet) as a contactless electromagnetic acoustic transducer (EMAT) for pulse echo operation at MHz frequencies. A pulsed ultrasound emission into a metallic test object is electromagnetically excited by
an intense MHz burst at up to 500 A through the 0.15 mm filaments of the transducer. Immediately thereafter, a smoother and quasi “DC-like” current of 100 A is applied for about 1 ms and allows an
echo detection. The ultrasonic pulse echo operation for a simple, compact, non-contacting copper coil is new. Application scenarios for compact transducer techniques include very narrow and
hostile environments, in which, e.g., quickly moving metal parts must be tested with only one, non-contacting ultrasound shot. The small transducer coil can be operated remotely with a cable
connection, separate from the much bulkier supply circuitry. Several options for more technical and fundamental progress are discussed.
The highly successful lecture series on the topic of measurement and sensor technologies as part of the IEEE Workshop at the University of Applied Sciences Ruhr West (HRW) is being continued in collaboration with the University of Siegen, the TU Chemnitz and the ITMO National Research University of Information Technologies, Mechanics and Optics in St. Petersburg. This time the event is featuring an even more international orientation by linking it with the Russian SENSORICA. The topics cover industrial and medical measurement technology as well as sensor technology in vehicles. Our event offers a platform for knowledge transfer between industry and public and commercial research institutions in the area of measurement technology.
This Abstract Book offers the opportunity of contacting speakers even after the event.
In addition we are very pleased to have selected contributions published in a special edition of the journal „tm Technisches Messen“ (De Gruyter Oldenbourg Verlag) again this year.
Um die Ziele der Bachelorarbeit schrittweise zu erreichen, wird im Folgenden eine Einführung in die DIN EN 80001-1 gegeben. Danach wird die Methode zur Einführung der Norm im AGAPLESION DIAKONIEKLINIKUM ROTENBURG präsentiert, wobei auf die Struktur der Dokumentation und die Einführung der Prozesse eingegangen wird. Im letzten Schritt wird die Implementierung anhand eines Beispiels durchgeführt. Hierbei wird geprüft, wie gut die Norm umsetzbar ist und welche Probleme dabei auftreten. In der Zusammenfassung werden alle Informationen verknüpft und die daraus resultierenden Probleme vorgestellt und anschließend diskutiert.