The development of innovative measuring technology for process optimization in hot rolling mills becomes more and more relevant because of increasing demands on product quality. Measurement technology for high-resolution non-contact cross-sectional area measurement has shown that the variation in cross-sectional area contains information about the rolling process. This information can be used for the development of new measurement devices and analytical methods for process optimization. The harsh environmental conditions and strict safety regulations result in great effort when implementing a new sensor prototype in hot rolling mills. For this reason, this work presents a mechatronic test stand that can simulate the cross-sectional area variation under laboratory conditions realistically.
The harmonic and interharmonic analysis recommendations are contained in the latest International Electrotechnical Commission (IEC) standards on power quality. Measurement and analysis experiences have shown that great difficulties arise in the interharmonics detection and measurement with acceptable levels of accuracy. In this paper, the spectral leakage problems of the discrete Fourier transform due to synchronization errors of interharmonics are analyzed. The time-domain averaging is investigated for the processing of harmonics in the framework of the IEC standards. A difference filter is proposed to detect interharmonics and can be compatible with the IEC standards. Simulations and the field results show the usefulness of the proposed methods.
Detection of air trapping in chronic obstructive pulmonary disease by low frequency ultrasound
(2012)
Background: Spirometry is regarded as the gold standard for the diagnosis of COPD, yet the condition is widely underdiagnosed. Therefore, additional screening methods that are easy to perform and to interpret are needed. Recently, we demonstrated that low frequency ultrasound (LFU) may be helpful for monitoring lung diseases. The objective of this study was to evaluate whether LFU can be used to detect air trapping in COPD. In addition, we evaluated the ability of LFU to detect the effects of short-acting bronchodilator medication.Methods: Seventeen patients with COPD and 9 healthy subjects were examined by body plethysmography and LFU. Ultrasound frequencies ranging from 1 to 40 kHz were transmitted to the sternum and received at the back during inspiration and expiration. The high pass frequency was determined from the inspiratory and the expiratory signals and their difference termed F. Measurements were repeated after inhalation of salbutamol.Results: We found signi ficant differences in F between COPD subjects and healthy subjects. These differences were already significant at GOLD stage 1 and increased with the severity of COPD. Sensitivity for detection of GOLD stage 1 was 83% and for GOLD stages worse than 1 it was 91%. Bronchodilator effects could not be detected reliably.Conclusions: We conclude that low frequency ultrasound is cost-effective, easy to perform and suitable for detecting air trapping. It might be useful in screening for COPD
Photoluminescence (PL) in GaN or InGaN layers monitored during epitaxial growth at high temperatures permits a quasi-continuous in situ characterization of opto-electronic properties. Therefore, epitaxial parameters can now be optimized at the earliest possible stage. A pulsed and high-power UV laser was required for PL excitation at high temperatures. Herein, the underlying nonlinear mechanism was studied via time-resolved PL experiments and rate equation-based modeling. A temperature-activated and saturable path for quenching over defects was identified. Beyond the saturation threshold, reasonably-intensive PL sets in. At high temperatures not only is the near band gap-PL present, but also—as a new observation—a defect-assisted PL emerges. Apart from these specific electronic transitions in high-temperature PL of GaN, a simple, but reasonably predictive model of the luminescent thin film has been set up to track down interference fringes in the PL spectra. It is worth mentioning that the spectral PL modulation (aiming at the Purcell effect) is often mixed up with ordinary Fabry–Pérot interference. A distinction has become key to properly analyze the spectral signatures of high-temperature PL in order to provide a reliable in situ characterization of GaN layers during epitaxial growth
Induktive Bioimpedanzmessung – Verbesserte örtliche Auflösung durch geeignete Spulengeometrien
(2013)
This experimental study demonstrates for the first time a solid-state circuitry and design for a simple compact copper coil (without an additional bulky permanent magnet or bulky electromagnet) as a contactless electromagnetic acoustic transducer (EMAT) for pulse echo operation at MHz frequencies. A pulsed ultrasound emission into a metallic test object is electromagnetically excited by
an intense MHz burst at up to 500 A through the 0.15 mm filaments of the transducer. Immediately thereafter, a smoother and quasi “DC-like” current of 100 A is applied for about 1 ms and allows an
echo detection. The ultrasonic pulse echo operation for a simple, compact, non-contacting copper coil is new. Application scenarios for compact transducer techniques include very narrow and
hostile environments, in which, e.g., quickly moving metal parts must be tested with only one, non-contacting ultrasound shot. The small transducer coil can be operated remotely with a cable
connection, separate from the much bulkier supply circuitry. Several options for more technical and fundamental progress are discussed.
A Large and Quick Induction Field Scanner for Examining the Interior of Extended Objects or Humans
(2017)
This study describes the techniques and signal properties of a large, powerful, and linear-scanning 1.5 MHz induction field scanner. The mechanical system is capable of quickly reading the volume of relative large objects, e.g., a test person. The general approach mirrors Magnetic Induction Tomography (MIT), but the details differ considerably from currently-described MIT systems: the setup is asymmetrical, and it operates in gradiometric modalities, either with coaxial excitation with destructive interference or with a single excitation loop and tilted receivers. Following this approach, the primary signals were almost completely nulled, and test objects' real or imaginary imprint was obtained directly. The coaxial gradiometer appeared advantageous: exposure to strong fields was reduced due to destructive interference. Meanwhile, the signals included enhanced components at higher spatial frequencies, thereby obtaining a gradually improved capability for localization. For robust signals, the excitation field can be powered towards the rated limits of human exposure to time-varying magnetic fields. Repeated measurements assessed the important signal integrity, which is affected by the scanner´s imperfections, particularly any motions or respiratory changes in living beings during or between repeated scans. The currently achieved and overall figure of merit for artifacts was 58 dB for inanimate test objects and 44 dB for a test person. Both numbers should be understood as worst case levels: a repeated scan with intermediate breathing and drift/dislocations requires 50 seconds, whereas a single measurement (with respiratory arrest) takes only about 5 seconds.
Die steigenden Anforderungen an den Umweltschutz bei möglichst niedrigen Kosten betreffen auch die öffentlichen Kanalnetze und Kläranlagen. Speziell die Kanalnetze sind über Jahrzehnte gewachsen, ohne dass kostengünstig eine genaue Bilanz ihrer Leistungsfähigkeit bis in ihre Segmente möglich war. Es fehlte vor allem in kleineren Systemen an Messwerten für die Transportmengen in Abhängigkeit der Witterung zur Beurteilung des Transportverhaltens der Einzelsegmente. Erst diese Messwerte ermöglichen eine mathematische Modellbildung mit Parametrierung und damit Ansätze für eine Optimierung. In diesem Beitrag wird der Prototyp eines neuartigen Sensors vorgestellt, der die gleichzeitige, kostengünstige und zeitbegrenzte Erfassung der Abwasserströme an verschiedenen Punkten im Kanalnetz ermöglichen soll. Die im Abwasserstrom befindlichen Teile des Sensors sind preiswerte mechanische Komponenten, die kostengünstig und einfach zu ersetzen sind. Die Erfassung der Strömungsgeschwindigkeit und der durchströmten Querschnittsfläche erfolgt mit Hilfe der sich an einem Störkörper einstellenden Druckverhältnisse.
In modernen Prüffeldern zur Warenendkontrolle dienen halbleitergesteuerte Frequenzumformer zur Einstellung der Drehzahl. Diese Systeme verursachen erhebliche Störungen der Strom- und Spannungssignale. Aus diesen Signalen müssen alle elektrischen Kenngrößen berechnet werden. Eine besondere Bedeutung haben dabei die Frequenz und Phasenlage. In diesem Beitrag wird ein mathematischer Algorithmus vorgestellt, der zur Berechnung von Frequenz und Phasenlage bei guter Unterdrückung dieser Störungen eingesetzt werden kann.
Im vorliegenden Beitrag wird das Phasen-Differenz-Verfahren zur Frequenzmessung der durch Rauschen gestörten Signale vorgestellt. Es wird gezeigt, dass Frequenzausreißer bei Anwendungen dieses Verfahrens entstehen, auch wenn das Signal-zu-Rausch-Verhältnis ausreichend groß ist. Die Ursachen der Frequenzausreißer werden analysiert. Zur Korrektur wird ein Lösungsansatz vorgeschlagen. Im Vergleich mit anderen Verfahren kann das verbesserte Phasen-Differenz-Verfahren die Frequenz der durch Rauschen gestörten Signale mit größerer Genauigkeit und vertretbarem Rechenaufwand berechnen.
Efficient photoluminescence (PL) spectra from GaN and InGaN layers at temperatures up to 1100 K are observed with low noise floor and high dynamic resolution. A number of detailed spectral features in the PL can be directly linked to physical properties of the epitaxial grown layer. The method is suggested as an in situ monitoring tool during epitaxy of nitride LED and laser structures. Layer properties like thickness, band gap or film temperature distribution are feasible.
Electro-magnetic acoustic transducers (EMATs) are intended as non-contact and non-destructive ultrasound transducers for metallic material. The transmitted intensities from EMATS are modest, particularly at notable lift off distances. Some time ago a concept for a “coil only EMAT” was presented, without static magnetic field. In this contribution, such compact “coil only EMATs” with effective areas of 1–5 cm2 were driven to excessive power levels at MHz frequencies, using pulsed power technologies. RF induction currents of 10 kA and tens of Megawatts are applied. With increasing power the electroacoustic conversion efficiency also increases. The total effect is of second order or quadratic, therefore non-linear and progressive, and yields strong ultrasound signals up to kW/cm2 at MHz frequencies in the metal. Even at considerable lift off distances (cm) the ultrasound can be readily detected. Test materials are aluminum, ferromagnetic steel and stainless steel (non-ferromagnetic). Thereby, most metal types are represented. The technique is compared experimentally with other non-contact methods: laser pulse induced ultrasound and spark induced ultrasound, both damaging to the test object’s surface. At small lift off distances, the intensity from this EMAT concept clearly outperforms the laser pulses or heavy spark impacts.
In this work we report the first quasi-continuous in-situ photoluminescence study of growing InGaN LED structures inside an industrial-grade metal-organic vapor phase epitaxy (MOVPE) reactor at growth temperature. The photoluminescence spectra contain information about temperature, thickness and composition of the epitaxial layers. Furthermore, the in-situ spectra – even at an early stage of the growth of the active region – can be used to predict the photoluminescence emission wavelength of the structure at room temperature. In this study an accuracy of this predicted wavelength in the range of ± 1.3 nm (2σ) is demonstrated. This technique thus appears suitable for closed-loop control of the emission wavelength of InGaN LEDs already during growth.
A simple copper coil without a voluminous stationary magnet can be utilized as a non-contacting transmitter and as a detector for ultrasonic vibrations in metals. Advantages of such compact EMATs without (electro-)magnet might be: applications in critical environments (hot, narrow, presence of iron filings…), potentially superior fields (then improved ultrasound transmission and more sensitive ultrasound detection).
The induction field of an EMAT strongly influences ultrasound transduction in the nearby metal. Herein, a simplified analytical method for field description at high liftoff is presented. Within certain limitations this method reasonably describes magnetic fields (and resulting eddy currents, inductances, Lorentz forces, acoustic pressures) of even complex coil arrangements. The methods can be adapted to conventional EMATS with a separate stationary magnet.
Increased distances (liftoff) are challenging and technically relevant, and this practical question is addressed: with limited electrical power and given free space between transducer and target metal, what would be the most efficient geometry of a circular coil? Furthermore, more complex coil geometries (“butterfly coil”) with a concentrated field and relatively higher reach are briefly investigated.
Wirbelströme werden in der Mess- und Sensortechnik sehr erfolgreich benutzt, um berührungslos Risse und Abstände metallischer Halbzeuge zu bestimmen. Die Messung von Konturen ist mit diesem industrietauglichen Wirkprinzip bisher nicht realisiert worden. Hier werden häufig optische Messsysteme eingesetzt. Speziell bei glühenden Werkstücken oder bei Benetzung der Halbzeuge mit Bohremulsionen und Schneidölen steigt der Aufwand für den Einsatz optischer Systeme stark an. Messverfahren, die auf hochfrequenten Wirbelströmen basieren, sind aufgrund ihrer einfachen Aufbauten deutlich robuster und somit besser für diese Anwendung geeignet. Voruntersuchungen zeigten, dass mit dieser Methode schon kleine Geometrieabweichungen des Walzgutes von wenigen Mikrometern detektiert werden können. In diesem Beitrag werden zwei Möglichkeiten zur Messung der spektralen Impedanzbeeinflussung eines Messschwingkreises durch die Wirbelströme im Werkstück gegenübergestellt.
The production and deformation of perforated sheets introduces high levels of mechanical stress into the material. In a significant fraction, such stress levels lead to crack formation in the processed sheets. Additionally, the material might be thinned and weakened in the exposed areas; these areas tend to crack at any later dates. Currently no measuring device for the detection of such material cracks or narrowing in perforated sheet metals is in practical use. Such device should be able to test the deformed circumference of the processed sheets within the very limited time of the production cycles. This paper describes the physical principles and a metrological implementation of a potential method for fast crack detection in perforated sheet metals. Even a critical material thinning - prior to the formation of a crack - can be observed. The measuring task appears to be solvable on the basis of high frequency electromagnetic fields.
Die steigenden Anforderungen der fertigenden Industrie an Halbzeuge wie Stahl- und Aluminiumblech führen zu großen Anstrengungen bei der Entwicklung neuer und Verbesserung alter Walztechniken. Einen wesentlichen Einfluss auf die erreichbaren Flächentoleranzen der Bleche hat neben der Walzenform die Temperaturverteilung an der Walzenoberfläche.
Increasing demands from the manufacturing industry on semifinished products such as steel and aluminium plate are leading to greater efforts in the development of new and the improvement of existing rolling techniques. In addition to the shape of the roll, temperature distribution on the roll surface has a significant influence on the surface tolerances of the sheets which may be achieved.
The transurethral resection (TUR) is a standard technique in urological treatment procedures. Both, monopolar and bipolar electrosurgical systems, are used for TUR. Whereas electrical and physical processes in surgery surroundings are well understood for monopolar systems, there is no sufficient data base for the assessment of the processes with the use of bipolar systems. In this context a multi-electrode measuring system was developed to visualize the spatial potential distribution around bipolar electrosurgical devices as a first step to risk analysis. To simulate the anatomic surroundings of a transurethral surgery a cylinder filled with isotonic saline solution is used as a complexity reduced experimental environment. Investigations about time stability and a qualitative assessment of the experimental set-up show deviations of measured values less than 5%. This is sufficient for further analysis of calculated power loss density distributions based on measured potential distributions. The spatial potential distribution around a bipolar devices is presented by horizontal and vertical sections through the experimental environment.
Die transurethrale Resektion der Prostata (TUR-P) ist der Gold Standard für die endoskopisch-chirurgische Behandlung der Benignen Prostatahyperplasie (BPH). Unbekannt ist jedoch, ob bei der bipolaren TUR-P die Möglichkeit von elektrothermischen Verletzung von benachbartem nichtopertiertem Gewebe besteht. Grund hierfür könnten höhere Ausgangsleistungen der Chirurgie-Generatoren sein. Deshalb werden experimentell gemessene Werte der räumlichen Verlustleistungsdichte um ein bipolares Resektoskop als Quellterm für die Berechnung der Temperaturänderung im operationsnahen Gewebe verwendet. Die Temperaturberechnung basiert auf der numerischen Lösung der Wärmeleitungsgleichung nach Penne. Für die gewählten Randbedingungen und Eingabeparameter sind keine signifikanten Temperaturerhöhungen im Berechnungsgebiet am proximalen Ende des Resektoskop-Schaftes festzustellen. Um ein umfassendes Verständnis zu gewinnen sollen weiterführende Untersuchungen mit einer Variation der Randbedingungen und Eingabeparameter durchgeführt werden
In dieser Veröffentlichung wird ein Konzept vorgestellt, das es erlaubt die Topologie der Magnetfelder bei der „Magnetischen Induktionstomografie“ (MIT) durch geometrische Spulenkonstruktionen und Bestromungsmuster soweit zu verändern, um eine scharfe Lokalisierung von Objekten innerhalb des Raumes zu ermöglichen. Ziel ist dabei, die Empfindlichkeit im Messvolumen gleichmäßiger als in der bekannten MIT zu verteilen, sodass elektrisch leitfähige Objekte mit größerer Entfernung zwischen Sender- und Empfängereinheit mit nahezu gleich hoher Signalintensität detektiert werden können, wie Objekte in Sender- und Empfängernähe. Dabei soll die maximale Objektgröße, die noch zu detektieren ist, verkleinert und die Empfindlichkeit des Systems verbessert werden.
To analyze the electric field around bipolar resectoscopes, used in urology, in terms of reasons for late complications after a surgical treatment a flexible multielectrode system was developed to measure the 3-D potential distribution. A high spatial resolution is achieved with the least possible individual measurements under the conditions of a quasi-static electric field. A flexible arrangement and positioning of the measuring points in the vertical direction of the experimental environment enable an adjustable spatial resolution and the selection of the region of interest. The existing influence of the multielectrode system on the measuring results is described and a correction method is presented to achieve significant results. Thus, the multielectrode system is usable for a comparative study of bipolar resectoscopes varying in the arrangement of resection and return electrode.
LEDs gelten als umweltfreundliche Beleuchtungstechnik. Für die Massenanwendung arbeiten die LED-Hersteller an einer Senkung der Kosten bzw. einer Erhöhung der Ausbeute, insbesondere bei der aufwendigen LED-Kristallbeschichtung auf den Wafern. Während der Beschichtung (MOCVD) werden optische In-situ-Messgeräte zur Überwachung des Prozesses genutzt. Die hier vorgestellte Untersuchung beschäftigt sich mit dem Einfluss von Super-Photolumineszenz-Effekten bei einer möglichen In-situ-Prozesskontrolle in der MOCVD.
Wirbelstromsensoren sind in der industriellen Messtechnik stark verbreitet. Insbesondere bei der Herstellung warmgewalzter Halbzeuge können sie durch ihre Robustheit gegenüber Wasserdampf und hohen Walzguttemperaturen überzeugen. Ein noch offenes Feld ist die In-Situ‐Detektion von Rissen im Draht während des Walzprozesses bei Walzgeschwindigkeiten bis zu 100 m/s und Materialtemperaturen bis zu 1200 ℃. Im Folgenden soll mittels der Finiten-Elemente-Analyse untersucht werden, wie sich Längsrisse im Draht auf Oberflächenströme und damit auf deren magnetische Flussdichte auswirken. Ziel ist es, Aussagen über den Einfluss verschiedener Rissbreiten und Risstiefen auf die magnetische Flussdichte zu machen und so einen möglichen Effekt auf einen Wirbelstromsensor untersuchen zu können.
Gallium Nitride (GaN) and Indium Gallium Nitride (InGaN) have become important semiconductor materials for the LED lighting industry. Recently, a photoluminescence (PL) technique for direct in-situ characterization of GaN and InGaN layers during epitaxial growth in a planetary metalorganic vapor phase epitaxy (MOVPE) reactor was reported. The PL signals reveal – at the earliest possible stage – information about current layer thickness, temperature, composition, surface roughness, and self-absorption. Thus, the PL data is valuable for both controlling and optimizing the growth parameters, thereby promising both better devices and a better yield for the LED industry. This technical report describes an extension of this PL technique to close coupled showerhead (CCS) reactors with narrow optical viewports. In contrast to the wide aperture optics in previous investigations, a compact and all-fiber optical probe without voluminous lens optics, filter elements or beam splitters was used.