Refine
Year of publication
- 2013 (37) (remove)
Document Type
- Article (16)
- Conference Proceeding (15)
- Part of Periodical (2)
- Book (1)
- Part of a Book (1)
- Course Material (1)
- Working Paper (1)
Language
- English (24)
- German (12)
- Multiple languages (1)
Is part of the Bibliography
- no (37)
Keywords
- Fachhochschule (2)
- Hochschule Ruhr West (2)
- Mülheim an der Ruhr (2)
- Zeitschrift (2)
The bipolar transurethral resection is a further development of monopolar transurethral resection, being the gold standard in surgical treatment of prostate and bladder diseases. To create the metrological basis for understanding of electrical and physical processes during bipolar transurethral resection an experimental set-up to visualize spatial potential distribution around bipolar devices was developed. A hardware based signal conditioning and specific undersampling are presented as data acquisition methods for a sampling rate up to 1 MS/s. These methods are compared with the possibilities of a high speed data acquisition card. For more than four measuring channels and depending on the output bandwidth of the electrosurgical generator either hardware based signal conditioning or specific undersampling is suggested.
It is common to have a large noise and/or a strong interference around the frequency band of a Power Line Communication (PLC) system due to the fact that the PLC channel is not designed for communication. If there are no efficient operations at the receiver to suppress this out-of-band noise and interference to some extent, the Signal-to-Noise Ratio (SNR) will decrease and system will suffer performance loss consequently. Normally, the effort of Analog Front End (AFE) on the suppression of out-of-band interference is finite and it is uneconomic to change the AFE structure to make a performance improvement. Therefore, an appropriate structure of Digital Front End (DFE) at the receiver is necessary to reduce the impact of out-of-band noise and interference furthermore. In this paper, three different kinds of DFE structure at the receiver are introduced: classic DFE, time domain Nyquist windowing and Equivalent Complex Baseband (ECB) approach. The performance of these DFE structures is compared, not only from the aspect of out-of-band suppression, but also from the system overhead they need.
Design and Evaluation of a Platform Independent Application for Mobile Access of Moodle Quizzes
(2013)
Die Entwicklung des automobilen HMI verläuft in immer kürzer werdenden Zyklen. Nichtsdestoweniger läßt sich kaum erahnen, inwieweit sich die Zukunft automobilen HMIs darstellen wird. Im Rahmen eines Experten-Workshops wurden verschiedene zukünftige Szenarien in 5, 10 und 20 Jahren auf Basis von Cockpitskizzen bearbeitet. Als Hilfestellung dienten hierbei drei unterschiedliche Personas, basierend auf verschiedenen prototypischen Kunden.
The transurethral resection (TUR) is a standard technique in urological treatment procedures. Both, monopolar and bipolar electrosurgical systems, are used for TUR. Whereas electrical and physical processes in surgery surroundings are well understood for monopolar systems, there is no sufficient data base for the assessment of the processes with the use of bipolar systems. In this context a multi-electrode measuring system was developed to visualize the spatial potential distribution around bipolar electrosurgical devices as a first step to risk analysis. To simulate the anatomic surroundings of a transurethral surgery a cylinder filled with isotonic saline solution was used as a complexity reduced experimental environment.
The transurethral resection (TUR) is a standard technique in urological treatment procedures. Both, monopolar and bipolar electrosurgical systems, are used for TUR. Whereas electrical and physical processes in surgery surroundings are well understood for monopolar systems, there is no sufficient data base for the assessment of the processes with the use of bipolar systems. In this context a multi-electrode measuring system was developed to visualize the spatial potential distribution around bipolar electrosurgical devices as a first step to risk analysis. To simulate the anatomic surroundings of a transurethral surgery a cylinder filled with isotonic saline solution is used as a complexity reduced experimental environment. Investigations about time stability and a qualitative assessment of the experimental set-up show deviations of measured values less than 5%. This is sufficient for further analysis of calculated power loss density distributions based on measured potential distributions. The spatial potential distribution around a bipolar devices is presented by horizontal and vertical sections through the experimental environment.