Refine
Year of publication
Document Type
- Conference Proceeding (29)
- Article (26)
- Bachelor Thesis (21)
- Book (8)
- Master's Thesis (6)
- Doctoral Thesis (4)
- Part of a Book (1)
- Part of Periodical (1)
Language
- German (58)
- English (35)
- Multiple languages (3)
Keywords
- Feldverteilung (1)
- GaN (1)
- Gallium (1)
- Gewebediagnostik (1)
- Halberzeugnis (1)
- Hochtemperatur (1)
- InGaN (1)
- Indium (1)
- Induktive Messsysteme (1)
- Inprozesskontrolle (1)
Institute
- Fachbereich 4 - Institut Mess- und Senstortechnik (96) (remove)
The bipolar transurethral resection is a further development of monopolar transurethral resection, being the gold standard in surgical treatment of prostate and bladder diseases. To create the metrological basis for understanding of electrical and physical processes during bipolar transurethral resection an experimental set-up to visualize spatial potential distribution around bipolar devices was developed. A hardware based signal conditioning and specific undersampling are presented as data acquisition methods for a sampling rate up to 1 MS/s. These methods are compared with the possibilities of a high speed data acquisition card. For more than four measuring channels and depending on the output bandwidth of the electrosurgical generator either hardware based signal conditioning or specific undersampling is suggested.
In der modernen Medizintechnik ist die zuverlässige Funktionsweise von Geräten von entscheidender Bedeutung. Diese Bachelorarbeit befasst sich mit dem Zustandsmonitoring von medizinischen Geräten, um die verschiedenen Zustände von medizinischen Geräte zu erfassen.
Das Monitoring hilft dabei, die tatsächliche Nutzungsfrequenz der Geräte zu ermitteln. Ein verbessertes Verständnis der Gerätenutzung kann dazu beitragen, Kosten zu senken und das Gerätemanagement in Krankenhäusern zu optimieren.
Das primäre Ziel dieser Arbeit war die Entwicklung einer Datenverarbeitungsmethode für das Zustandsmonitoring von Medizingeräten mittels energiesparender Funk-Sensoren. Oftmals werden in Krankenhäusern mehr Geräte angeschafft als benötigt, und dennoch müssen alle Geräte gewartet werden, selbst wenn einige selten in Betrieb sind. Dies resultiert in unnötigen Kosten und Ausfallzeiten.
Für die Untersuchung wurde ein energiesparender Funksensor eingesetzt, der mit einem Stromsensor ausgestattet ist. Dieser erfasst den Stromfluss der angeschlossenen Geräte und kommuniziert online über das IoT. Die erfassten Daten wurden komprimiert und an das TTN (The Things Network) übertragen. Ein KI-Modell wurde mit den gesammelten Daten trainiert, um die verschiedenen Zustände der Geräte zu erkennen.
Die wichtigsten Ergebnisse zeigen, dass die Zustände der Geräte variieren und typischerweise in "AN", "AUS", "Idle-Modus" und "Im Betrieb" kategorisiert werden können. Sobald der Stromfluss einen bestimmten Wert erreicht, kann die KI bestimmen, in welchem Zustand sich das Gerät befindet. Dies bietet eine wertvolle Grundlage für ein verbessertes Management und Wartungssystem in Krankenhäusern.
Detection of air trapping in chronic obstructive pulmonary disease by low frequency ultrasound
(2012)
Background: Spirometry is regarded as the gold standard for the diagnosis of COPD, yet the condition is widely underdiagnosed. Therefore, additional screening methods that are easy to perform and to interpret are needed. Recently, we demonstrated that low frequency ultrasound (LFU) may be helpful for monitoring lung diseases. The objective of this study was to evaluate whether LFU can be used to detect air trapping in COPD. In addition, we evaluated the ability of LFU to detect the effects of short-acting bronchodilator medication.Methods: Seventeen patients with COPD and 9 healthy subjects were examined by body plethysmography and LFU. Ultrasound frequencies ranging from 1 to 40 kHz were transmitted to the sternum and received at the back during inspiration and expiration. The high pass frequency was determined from the inspiratory and the expiratory signals and their difference termed F. Measurements were repeated after inhalation of salbutamol.Results: We found signi ficant differences in F between COPD subjects and healthy subjects. These differences were already significant at GOLD stage 1 and increased with the severity of COPD. Sensitivity for detection of GOLD stage 1 was 83% and for GOLD stages worse than 1 it was 91%. Bronchodilator effects could not be detected reliably.Conclusions: We conclude that low frequency ultrasound is cost-effective, easy to perform and suitable for detecting air trapping. It might be useful in screening for COPD
Wirbelstromsensoren sind in der industriellen Messtechnik stark verbreitet. Insbesondere bei der Herstellung warmgewalzter Halbzeuge können sie durch ihre Robustheit gegenüber Wasserdampf und hohen Walzguttemperaturen überzeugen. Ein noch offenes Feld ist die In-Situ‐Detektion von Rissen im Draht während des Walzprozesses bei Walzgeschwindigkeiten bis zu 100 m/s und Materialtemperaturen bis zu 1200 ℃. Im Folgenden soll mittels der Finiten-Elemente-Analyse untersucht werden, wie sich Längsrisse im Draht auf Oberflächenströme und damit auf deren magnetische Flussdichte auswirken. Ziel ist es, Aussagen über den Einfluss verschiedener Rissbreiten und Risstiefen auf die magnetische Flussdichte zu machen und so einen möglichen Effekt auf einen Wirbelstromsensor untersuchen zu können.
In this scientific research, an innovative sensor system is developed to prevent child heatstrokes in vehicles. The system incorporates a 24 GHz Continuous-Wave (CW) radar system, which identifies vital signs of an infant through a 4-by-1 patch antenna array embedded in a specifically designed circuit board. Intelligent signal processing algorithms analyze data generated by the radar chip and execute processing tasks on a robust microcontroller. The child’s respiration
rate can be extracted qualitatively from the data in nearly real-time, enabling the system to differentiate between a child and a mere shopping bag on the seat. In the event of identifying a critical condition, the system transmits this information via a data bus to a central ECU within the vehicle. This ECU is integrated with GSM and GPS connections, allowing communication with the driver or emergency services. The development of the sensor system adheres to existing
automotive industry standards, featuring a cost-effective design intended as a prototype for large-scale production. Through rigorous evaluation across various scenarios, including realworld
situations with children, the sensor system is refined. The continuously reliable function of the developed radar-based sensor system holds the potential to save children’s lives, making
a major contribution to automotive safety.