The development of innovative measuring technology for process optimization in hot rolling mills becomes more and more relevant because of increasing demands on product quality. Measurement technology for high-resolution non-contact cross-sectional area measurement has shown that the variation in cross-sectional area contains information about the rolling process. This information can be used for the development of new measurement devices and analytical methods for process optimization. The harsh environmental conditions and strict safety regulations result in great effort when implementing a new sensor prototype in hot rolling mills. For this reason, this work presents a mechatronic test stand that can simulate the cross-sectional area variation under laboratory conditions realistically.
Untersuchung des Einflusses von Längsrissen in Drähten auf die Impedanz eines Wirbelstromsensors
(2012)
Velocity Approximation of Hot Steel Rods Using Frequency Spectroscopy of the Cross-Section Area
(2019)
In this work, an approach for velocity approximation of hot steel rods based on frequency spectroscopy is presented. For this purpose, a sensor already implemented in a rolling mill for measuring the cross-sectional area of the rolling stock is used to obtain information about the velocity of the hot rods. Moreover, the effect of forward slip is briefly discussed.
Rolling mills are continually improved and opti-mized by implementing innovative technology to decrease costs and scrap. Despite of the progressive automation and experience, some important process parameters can still not be determined with sufficient accuracy. As part of the research project PIREF, the velocity of the hot rolled rod shall be measured by using im-pedance analysis to estimate the volumetric flow rate of the mate-rial. For a high accuracy measurement of the impedance, a pow-erful VNA is used. To minimize errors in the measurement, caused by e.g. temperature drift, a correction of the measurement fre-quency is needed. This must be achieved without recalibration of the VNA to avoid faulty behavior of the online control. To solve this problem, an approach based on a polynomial regression is presented in this work.
Im vorliegenden Beitrag wird das Phasen-Differenz-Verfahren zur Frequenzmessung der durch Rauschen gestörten Signale vorgestellt. Es wird gezeigt, dass Frequenzausreißer bei Anwendungen dieses Verfahrens entstehen, auch wenn das Signal-zu-Rausch-Verhältnis ausreichend groß ist. Die Ursachen der Frequenzausreißer werden analysiert. Zur Korrektur wird ein Lösungsansatz vorgeschlagen. Im Vergleich mit anderen Verfahren kann das verbesserte Phasen-Differenz-Verfahren die Frequenz der durch Rauschen gestörten Signale mit größerer Genauigkeit und vertretbarem Rechenaufwand berechnen.
Wirbelströme werden in der Mess- und Sensortechnik sehr erfolgreich benutzt, um berührungslos Risse und Abstände metallischer Halbzeuge zu bestimmen. Die Messung von Konturen ist mit diesem industrietauglichen Wirkprinzip bisher nicht realisiert worden. Hier werden häufig optische Messsysteme eingesetzt. Speziell bei glühenden Werkstücken oder bei Benetzung der Halbzeuge mit Bohremulsionen und Schneidölen steigt der Aufwand für den Einsatz optischer Systeme stark an. Messverfahren, die auf hochfrequenten Wirbelströmen basieren, sind aufgrund ihrer einfachen Aufbauten deutlich robuster und somit besser für diese Anwendung geeignet. Voruntersuchungen zeigten, dass mit dieser Methode schon kleine Geometrieabweichungen des Walzgutes von wenigen Mikrometern detektiert werden können. In diesem Beitrag werden zwei Möglichkeiten zur Messung der spektralen Impedanzbeeinflussung eines Messschwingkreises durch die Wirbelströme im Werkstück gegenübergestellt.