Refine
Year of publication
Document Type
- Conference Proceeding (25)
- Article (17)
- Book (4)
- Part of a Book (1)
Language
- German (24)
- English (21)
- Multiple languages (2)
Has Fulltext
- no (47)
Is part of the Bibliography
- no (47)
The development of innovative measuring technology for process optimization in hot rolling mills becomes more and more relevant because of increasing demands on product quality. Measurement technology for high-resolution non-contact cross-sectional area measurement has shown that the variation in cross-sectional area contains information about the rolling process. This information can be used for the development of new measurement devices and analytical methods for process optimization. The harsh environmental conditions and strict safety regulations result in great effort when implementing a new sensor prototype in hot rolling mills. For this reason, this work presents a mechatronic test stand that can simulate the cross-sectional area variation under laboratory conditions realistically.
Influencing Parameters on Measuring the Cross-Section Area of Hot Rolled Rods in Steel Industries
(2014)
Wirbelstromsensoren sind in der industriellen Messtechnik stark verbreitet. Insbesondere bei der Herstellung warmgewalzter Halbzeuge können sie durch ihre Robustheit gegenüber Wasserdampf und hohen Walzguttemperaturen überzeugen. Ein noch offenes Feld ist die In-Situ‐Detektion von Rissen im Draht während des Walzprozesses bei Walzgeschwindigkeiten bis zu 100 m/s und Materialtemperaturen bis zu 1200 ℃. Im Folgenden soll mittels der Finiten-Elemente-Analyse untersucht werden, wie sich Längsrisse im Draht auf Oberflächenströme und damit auf deren magnetische Flussdichte auswirken. Ziel ist es, Aussagen über den Einfluss verschiedener Rissbreiten und Risstiefen auf die magnetische Flussdichte zu machen und so einen möglichen Effekt auf einen Wirbelstromsensor untersuchen zu können.
Untersuchung des Einflusses von Längsrissen in Drähten auf die Impedanz eines Wirbelstromsensors
(2012)
In modernen Prüffeldern zur Warenendkontrolle dienen halbleitergesteuerte Frequenzumformer zur Einstellung der Drehzahl. Diese Systeme verursachen erhebliche Störungen der Strom- und Spannungssignale. Aus diesen Signalen müssen alle elektrischen Kenngrößen berechnet werden. Eine besondere Bedeutung haben dabei die Frequenz und Phasenlage. In diesem Beitrag wird ein mathematischer Algorithmus vorgestellt, der zur Berechnung von Frequenz und Phasenlage bei guter Unterdrückung dieser Störungen eingesetzt werden kann.
The harmonic and interharmonic analysis recommendations are contained in the latest International Electrotechnical Commission (IEC) standards on power quality. Measurement and analysis experiences have shown that great difficulties arise in the interharmonics detection and measurement with acceptable levels of accuracy. In this paper, the spectral leakage problems of the discrete Fourier transform due to synchronization errors of interharmonics are analyzed. The time-domain averaging is investigated for the processing of harmonics in the framework of the IEC standards. A difference filter is proposed to detect interharmonics and can be compatible with the IEC standards. Simulations and the field results show the usefulness of the proposed methods.
The transurethral resection (TUR) is a standard technique in urological treatment procedures. Both, monopolar and bipolar electrosurgical systems, are used for TUR. Whereas electrical and physical processes in surgery surroundings are well understood for monopolar systems, there is no sufficient data base for the assessment of the processes with the use of bipolar systems. In this context a multi-electrode measuring system was developed to visualize the spatial potential distribution around bipolar electrosurgical devices as a first step to risk analysis. To simulate the anatomic surroundings of a transurethral surgery a cylinder filled with isotonic saline solution was used as a complexity reduced experimental environment.
The transurethral resection (TUR) is a standard technique in urological treatment procedures. Both, monopolar and bipolar electrosurgical systems, are used for TUR. Whereas electrical and physical processes in surgery surroundings are well understood for monopolar systems, there is no sufficient data base for the assessment of the processes with the use of bipolar systems. In this context a multi-electrode measuring system was developed to visualize the spatial potential distribution around bipolar electrosurgical devices as a first step to risk analysis. To simulate the anatomic surroundings of a transurethral surgery a cylinder filled with isotonic saline solution is used as a complexity reduced experimental environment. Investigations about time stability and a qualitative assessment of the experimental set-up show deviations of measured values less than 5%. This is sufficient for further analysis of calculated power loss density distributions based on measured potential distributions. The spatial potential distribution around a bipolar devices is presented by horizontal and vertical sections through the experimental environment.