621.3 Elektrotechnik, Elektronik
Refine
Year of publication
- 2014 (12) (remove)
Document Type
- Article (5)
- Conference Proceeding (4)
- Book (1)
- Part of a Book (1)
- Doctoral Thesis (1)
Language
- German (5)
- English (5)
- Multiple languages (2)
Is part of the Bibliography
- no (12)
Keywords
- Halberzeugnis (1)
- Hochtemperatur (1)
- Inprozesskontrolle (1)
- Rundstahl (1)
- Warmwalzen (1)
To analyze the electric field around bipolar resectoscopes, used in urology, in terms of reasons for late complications after a surgical treatment a flexible multielectrode system was developed to measure the 3-D potential distribution. A high spatial resolution is achieved with the least possible individual measurements under the conditions of a quasi-static electric field. A flexible arrangement and positioning of the measuring points in the vertical direction of the experimental environment enable an adjustable spatial resolution and the selection of the region of interest. The existing influence of the multielectrode system on the measuring results is described and a correction method is presented to achieve significant results. Thus, the multielectrode system is usable for a comparative study of bipolar resectoscopes varying in the arrangement of resection and return electrode.
Wirbelstromsensoren sind in der industriellen Messtechnik stark verbreitet. Insbesondere bei der Herstellung warmgewalzter Halbzeuge können sie durch ihre Robustheit gegenüber Wasserdampf und hohen Walzguttemperaturen überzeugen. Ein noch offenes Feld ist die In-Situ‐Detektion von Rissen im Draht während des Walzprozesses bei Walzgeschwindigkeiten bis zu 100 m/s und Materialtemperaturen bis zu 1200 ℃. Im Folgenden soll mittels der Finiten-Elemente-Analyse untersucht werden, wie sich Längsrisse im Draht auf Oberflächenströme und damit auf deren magnetische Flussdichte auswirken. Ziel ist es, Aussagen über den Einfluss verschiedener Rissbreiten und Risstiefen auf die magnetische Flussdichte zu machen und so einen möglichen Effekt auf einen Wirbelstromsensor untersuchen zu können.
Influencing Parameters on Measuring the Cross-Section Area of Hot Rolled Rods in Steel Industries
(2014)
We present a study on 3D based hand pose recognition using a new generation of low-cost time-of-flight(ToF) sensors intended for outdoor use in automotive human-machine interaction. As signal quality is impaired compared to Kinect-type sensors, we study several ways to improve performance when a large number of gesture classes is involved. We investigate the performance of different 3D descriptors, as well as the fusion of two ToF sensor streams. By basing a data fusion strategy on the fact that multilayer perceptrons can produce normalized confidences individually for each class, and similarly by designing information-theoretic online measures for assessing confidences of decisions, we show that appropriately chosen fusion strategies can improve overall performance to a very satisfactory level. Real-time capability is retained as the used 3D descriptors, the fusion strategy as well as the online confidence measures are computationally efficient.
Optimization of Encircling Eddy Current Sensors for Online Monitoring of Hot Rolled Round Steel Bars
(2014)
Modern manufacturing industries are continually working on quality enhancements for the hot rolling process of round products. One method for improving the finalisation of the rods is the implementation of an automatic size control system. As a result of these trends over the last few years, there has been an increasing demand for more accurate online measurements. Thus the reason for the research performed for this thesis. A particular challenge throughout this research was dealing with the temperature changes (up to 1200°C) from the in- and output of the fervent rolling stocks, and the effect this temperature changes had on the sensors. Furthermore, there is also high demand for developing fast and practical electronic measuring equipment, capable of measuring during high transport velocities (up to 120 m/s). The eddy current principle is just one of the very few methods available which can with-stand such harsh industrial environments. In fact, eddy current sensors are already being integrated into online monitoring tasks for hot rolling processes. The measurement uncertainty, however, is still considerably large for process control purposes. One reason for this lies within the ability for eddy current detectors to receive signals influenced by outward forces, i.e. forces dependent on its location, its geometry, the outside temperature and the material properties of a particular target. Thus the current accuracy for a cross-sectional area measurement, for example, is no higher than 1%. As a result, this thesis investigates the magnitude of all individual influential factors on the eddy current detectors, using model-based analysis techniques. The analytical model provides a solution for all rotationally symmetrical targets and the FEA model covers all of the other influencing parameters in a more time consuming manner. This thesis then provides different methods which are developed to separate the cross-sectional area measurement of a rod from all of the other influencing parameters. In addition, a material tracking approach for round products is developed. Two different kinds of prototypes, capable of measuring approximately 466 Tons of red-hot steel rods during the production process, are finally introduced in this thesis. The usefulness of the eddy current principle is validated by the provided field test results. The count accuracy for the identification of 2876 bars was found to be 99.93%, and the average measurement accuracy for the cross-sectional area experiments was reduced to ± 0.29 % when including all of the findings.
Efficient photoluminescence (PL) spectra from GaN and InGaN layers at temperatures up to 1100 K are observed with low noise floor and high dynamic resolution. A number of detailed spectral features in the PL can be directly linked to physical properties of the epitaxial grown layer. The method is suggested as an in situ monitoring tool during epitaxy of nitride LED and laser structures. Layer properties like thickness, band gap or film temperature distribution are feasible.
Bipolar electrosurgical systems are used for the treatment of benign prostatic hyperplasia (BPH) in urology. In order to analyse electrothermal processes during surgery the power loss density distribution around a bipolar resectoscope is calculated out of the measured potential distribution in isotonic saline solution ex situ. During further analysis power loss density values act as input for the Penne's bioheat equation. To achieve results, which are as realistic as possible, a method to obtain power loss density values, depending on the observed tissue or medium in the operating field, is presented. Applying this method, the power loss density distribution in isotonic saline solution at 25 °C is compared to the distribution calculated for the average conductivity of biological tissue in the region of interest.
LEDs gelten als umweltfreundliche Beleuchtungstechnik. Für die Massenanwendung arbeiten die LED-Hersteller an einer Senkung der Kosten bzw. einer Erhöhung der Ausbeute, insbesondere bei der aufwendigen LED-Kristallbeschichtung auf den Wafern. Während der Beschichtung (MOCVD) werden optische In-situ-Messgeräte zur Überwachung des Prozesses genutzt. Die hier vorgestellte Untersuchung beschäftigt sich mit dem Einfluss von Super-Photolumineszenz-Effekten bei einer möglichen In-situ-Prozesskontrolle in der MOCVD.