621.3 Elektrotechnik, Elektronik
Refine
Year of publication
Document Type
- Article (26)
- Conference Proceeding (24)
- Book (5)
- Part of a Book (2)
- Doctoral Thesis (2)
- Bachelor Thesis (1)
- Part of Periodical (1)
Language
- English (33)
- German (25)
- Multiple languages (3)
Is part of the Bibliography
- no (61)
Keywords
- GaN (1)
- Gallium (1)
- Halberzeugnis (1)
- Hochtemperatur (1)
- InGaN (1)
- Indium (1)
- Inprozesskontrolle (1)
- LED (1)
- Licht emittierende Dioden (1)
- MOVPE (1)
Die folgende Bachelorarbeit analysiert und wertet die Messdaten eines Niederschlagsensors aus, der auf dem induktiven Wirbelstromprinzip aufbaut. Der Sensor wird an der Hochschule Ruhr West im Institut für Mess- und Sensortechnik entwickelt. Er soll nach erfolgreicher Konfiguration die Niederschlagsintensität und die Tropfengröße über die Resonanzfrequenz der Spule ausgeben können. Um dieses Ziel zu erreichen, gibt die Bachelorarbeit eine Einschätzung, inwieweit das System für eine Niederschlagserfassung geeignet ist und welche Verbesserungen vorgenommen werden können. Dazu wurden die Messdaten in einer Regenkammer der Firma Lambrecht meteo GmbH erfasst. Für die Versuche wurden zwei Flachspulen mit Resonanzfrequenzen von 1,7 MHz und 8 MHz nacheinander ausgewertet. Die resultierenden Messdaten werden sowohl im Zeit- als auch im Frequenzbereich auf Verhaltensmuster und Kennwerte untersucht. Aus den Ergebnissen geht hervor, dass der Sensor aufgrund von äußeren Einflüssen und inneren Verhaltensweisen keine signifikante Antwort auf den Niederschlag ausgibt, um die Niederschlagsintensität und die Tropfengröße zu ermitteln. Dennoch zeigt sich, dass die Resonanzfrequenz der Spulen gegensätzliche Reaktionen hervorruft. Die Spule mit der Resonanzfrequenz von 1,7 MHz reagiert deutlich unempfindlicher auf äußere Einflüsse wie parasitäre Kapazitäten. Allerdings werden nur Regentropfeneinschläge bei hohen Niederschlagsmengen deutlich erkannt. Die Spule mit der Resonanzfrequenz von 8 MHz hingegen zeigt ein empfindlicheres Verhalten auf äußere Einflüsse. Zur Optimierung des Niederschlagssensors, muss dieser konfiguriert werden, damit er äußeren Einflüssen robust entgegenwirkt und den Niederschlag sensibel genug detektiert. Zudem müssen Ausreißer, die in der Frequenzanalyse entdeckt wurden und von den inneren Verhaltensweisen stammen, entfernt werden.
To reduce the number of traffic accidents and to increase the drivers comfort, the thought of designing driver assistance systems arose in the past years. Fully or partly autonomously guided vehicles, particularly for road traffic, pose high demands on the development of reliable algorithms. Principal problems are caused by having a moving observer in predominantly natural environments. At the Institut fur Neuroinformatik methods for analyzing driving relevant scenes by computer vision are developed in cooperation with several partners from the automobile industry. We present a solution for a driver assistance system. We concentrate on the aspects of video-based scene analysis and organization of behavior.
Quality and dimensional accuracy of hot rolled steel rods depend on several process parameters. In fact many of these crucial parameters are not be sufficiently determined yet. By improving automation and process control costs and scrap of production can be decreased. As part of the research project PIREF, one of these parameters – the roll gap – is under investigation beside other topics. Before starting rolling, the roll gap is typically set to a fixed value according to the planed dimensions of the product, but the forces during the rolling of the rod cause an enlargement of the roll gap. In which way the rolls change their position and form shall be examined in our research project. Therefore a first experimental setup has been built up to determine the change in position of the rolls under applied force. This is realized by a pot core coil as sensor using impedance analysis. The first results are presented in this work as a proof-of-principle.
Methods of red-hot rod shape testing require a robust non-contact measurement principle as a touch point could lead to damages to the rod and the detection unit. Therefore a new basic approach based on high frequency eddy current (HFEC) has been investigated. Due to the robustness and the ability to determine the rod shape even above the Curie temperature this principle is especially well suited and can be implemented in the production process directly. The first automatic measurement setup was successfully developed with promising results. Hereby a defect of ovality was detected with a parallel RLC-oscillator. The capacity of this RLC-oscillator is constant whereas the inductance is the measurement part that varies due to eddy current interactions with the rod.
Process Monitoring in Steel-Mills using Impedance Analysis: VNA Improvement for Data Acquisition
(2017)
The process automation extends over every manufacturing step of a product in the steel-mill to increase the quality, quantity and energy efficiency. The product dimensions are an important part of the quality control; these must maintain the specified tolerances. Additional to the cross-sectional-area, the measured data contains much more information about the manufacturing process, e.g. eccentricity, condition of the rolls and defects of the rod. For analyzing the measured data and to gather more information about the manufacturing process it is necessary to increase the speed of the data acquisition by performing some modifications of the VNA, e.g. faster analog to digital converter and microcontroller, improved firmware and optimized values of the passive electrical components for faster time constants and transient responses.
Bipolar electrosurgical systems are used for the treatment of benign prostatic hyperplasia (BPH) in urology. In order to analyse electrothermal processes during surgery the power loss density distribution around a bipolar resectoscope is calculated out of the measured potential distribution in isotonic saline solution ex situ. During further analysis power loss density values act as input for the Penne's bioheat equation. To achieve results, which are as realistic as possible, a method to obtain power loss density values, depending on the observed tissue or medium in the operating field, is presented. Applying this method, the power loss density distribution in isotonic saline solution at 25 °C is compared to the distribution calculated for the average conductivity of biological tissue in the region of interest.
Photolumineszenz (PL) aus Halbleiterstrukturen liefert Informationen bezüglich verschiedener Materialparameter wie z.B. Bandlücke, Schichtdicke sowie Temperatur. PL-Messungen werden klassischerweise erst ex situ und somit nach dem Produktionsprozess vorgenommen. Wird eine derartige PL-Messung während der Epitaxie einer Halbleiterstruktur und den damit verbundenen hohen Wachstumstemperaturen durchgeführt, erlaubt dies eine quasi-kontinuierliche In-situ-Charakterisierung der optoelektronischen Eigenschaften dieser Struktur zum frühestmöglichen Zeitpunkt, also noch in der Produktionsphase. Hierdurch wird eine In-situ-Optimierung der Prozessparameter ermöglicht, welche bei einer Ex-situ-Messung nicht gegeben ist. Die vorliegende Arbeit beschreibt zunächst theoretisch und dann anhand praktischer Messungen an industrienahen Epitaxie-Anlagen erstmals eine quasi-kontinuierliche In-situ-PL-Messung am Beispiel von wachsenden Nitrid-Halbleiterstrukturen. Über zeitaufgelöste PL-Messungen wird ein temperaturabhängiger Quenching-Mechanismus bei Gallium-Nitrid (GaN) und Indium-Gallium-Nitrid (InGaN) aufgezeigt, welcher den Einsatz von gepulsten Lasern als PL-Anregungsquelle bei hohen Wachstumstemperaturen einer Epitaxie erforderlich macht. Mit In-situ-PL-Messungen können hierdurch erstmals verschiedene Parameter einer gerade wachsenden Halbleiterschicht charakterisiert werden. Neben der Bestimmung der Temperatur und der Schichtdicke einer wachsenden, auf InGaN basierten LED-Struktur wird auch die Möglichkeit demonstriert, in einem frühen Stadium des Wachstums einer LED-Struktur ihre spätere Emissionswellenlänge bei Raumtemperatur vorherzusagen, und dies mit einer Genauigkeit von ± 1,3 nm (2σ). Diese Arbeit zeigt somit neben den industriell etablierten Messtechniken, wie z.B. pyrometrische Verfahren, eine weitere Möglichkeit zur Prozessüberwachung einer Epitaxie auf.
Efficient photoluminescence (PL) spectra from GaN and InGaN layers at temperatures up to 1100 K are observed with low noise floor and high dynamic resolution. A number of detailed spectral features in the PL can be directly linked to physical properties of the epitaxial grown layer. The method is suggested as an in situ monitoring tool during epitaxy of nitride LED and laser structures. Layer properties like thickness, band gap or film temperature distribution are feasible.