To analyze the electric field around bipolar resectoscopes, used in urology, in terms of reasons for late complications after a surgical treatment a flexible multielectrode system was developed to measure the 3-D potential distribution. A high spatial resolution is achieved with the least possible individual measurements under the conditions of a quasi-static electric field. A flexible arrangement and positioning of the measuring points in the vertical direction of the experimental environment enable an adjustable spatial resolution and the selection of the region of interest. The existing influence of the multielectrode system on the measuring results is described and a correction method is presented to achieve significant results. Thus, the multielectrode system is usable for a comparative study of bipolar resectoscopes varying in the arrangement of resection and return electrode.
Die transurethrale Resektion der Prostata (TUR-P) ist der Gold Standard für die endoskopisch-chirurgische Behandlung der Benignen Prostatahyperplasie (BPH). Unbekannt ist jedoch, ob bei der bipolaren TUR-P die Möglichkeit von elektrothermischen Verletzung von benachbartem nichtopertiertem Gewebe besteht. Grund hierfür könnten höhere Ausgangsleistungen der Chirurgie-Generatoren sein. Deshalb werden experimentell gemessene Werte der räumlichen Verlustleistungsdichte um ein bipolares Resektoskop als Quellterm für die Berechnung der Temperaturänderung im operationsnahen Gewebe verwendet. Die Temperaturberechnung basiert auf der numerischen Lösung der Wärmeleitungsgleichung nach Penne. Für die gewählten Randbedingungen und Eingabeparameter sind keine signifikanten Temperaturerhöhungen im Berechnungsgebiet am proximalen Ende des Resektoskop-Schaftes festzustellen. Um ein umfassendes Verständnis zu gewinnen sollen weiterführende Untersuchungen mit einer Variation der Randbedingungen und Eingabeparameter durchgeführt werden
The bipolar transurethral resection is a further development of monopolar transurethral resection, being the gold standard in surgical treatment of prostate and bladder diseases. To create the metrological basis for understanding of electrical and physical processes during bipolar transurethral resection an experimental set-up to visualize spatial potential distribution around bipolar devices was developed. A hardware based signal conditioning and specific undersampling are presented as data acquisition methods for a sampling rate up to 1 MS/s. These methods are compared with the possibilities of a high speed data acquisition card. For more than four measuring channels and depending on the output bandwidth of the electrosurgical generator either hardware based signal conditioning or specific undersampling is suggested.
Wirbelstromsensoren sind in der industriellen Messtechnik stark verbreitet. Insbesondere bei der Herstellung warmgewalzter Halbzeuge können sie durch ihre Robustheit gegenüber Wasserdampf und hohen Walzguttemperaturen überzeugen. Ein noch offenes Feld ist die In-Situ‐Detektion von Rissen im Draht während des Walzprozesses bei Walzgeschwindigkeiten bis zu 100 m/s und Materialtemperaturen bis zu 1200 ℃. Im Folgenden soll mittels der Finiten-Elemente-Analyse untersucht werden, wie sich Längsrisse im Draht auf Oberflächenströme und damit auf deren magnetische Flussdichte auswirken. Ziel ist es, Aussagen über den Einfluss verschiedener Rissbreiten und Risstiefen auf die magnetische Flussdichte zu machen und so einen möglichen Effekt auf einen Wirbelstromsensor untersuchen zu können.